Cena s DPH / bez DPH
Hlavní stránka>24/30478132 DC BS EN 15991 Testing of ceramic raw materials and ceramic materials. Direct determination of mass fractions of impurities in powders and granules of silicon carbide by inductively coupled plasma optical emission spectrometry with electrothermal vaporisation (ETV-ICP-OES)
sklademVydáno: 2024-06-27
24/30478132 DC BS EN 15991 Testing of ceramic raw materials and ceramic materials. Direct determination of mass fractions of impurities in powders and granules of silicon carbide by inductively coupled plasma optical emission spectrometry with electrothermal vaporisation (ETV-ICP-OES)

24/30478132 DC

BS EN 15991 Testing of ceramic raw materials and ceramic materials. Direct determination of mass fractions of impurities in powders and granules of silicon carbide by inductively coupled plasma optical emission spectrometry with electrothermal vaporisation (ETV-ICP-OES)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
600 Kč
Anglicky Tisk
Skladem
600 Kč
Označení normy:24/30478132 DC
Počet stran:30
Vydáno:2024-06-27
Status:Draft for Comment
Popis

24/30478132 DC


This standard 24/30478132 DC BS EN 15991 Testing of ceramic raw materials and ceramic materials. Direct determination of mass fractions of impurities in powders and granules of silicon carbide by inductively coupled plasma optical emission spectrometry with electrothermal vaporisation (ETV-ICP-OES) is classified in these ICS categories:
  • 81.060.10 Raw materials
This document defines a method for the determination of the mass fractions of the elements Al, Ca, Cr, Cu, Fe, Mg, Ni, Ti, V and Zr in powdered and granular silicon carbide. Dependent on element, emission lines, plasma conditions and sample mass, this test method is applicable for mass fractions of the above trace contaminations from about 0,1 mg/kg to about 1 000 mg/kg, after evaluation also from 0,001 mg/kg to about 5 000 mg/kg. NOTE 1 Generally for optical emission spectrometry using inductively coupled plasma and electrothermal vaporization (ETV-ICP-OES) there is a linear working range of up to four orders of magnitude. This range can be expanded for the respective elements by variation of the sample mass or by choosing emission lines with different sensitivity. After adequate verification, this document is also applicable to further metallic elements (excepting Rb and Cs) and some non-metallic contaminations (like P and S) and other allied non-metallic powdered or granular materials like carbides, nitrides, graphite, soot, coke, coal, and some other oxidic materials (see [1], [4], [5], [6], [7], [8], [9] and [10]). NOTE 2 There is positive experience with materials like, for example, graphite, boron carbide (B4C), silicon nitride (Si3N4), boron nitride (BN) and several metal oxides as well as with the determination of P and S in some of these materials.