Hlavní stránka>ASTM C1126-19 - Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation
Vydáno: 01.04.2019

ASTM C1126-19 - Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

Formát
Dostupnost
Cena a měna
Anglicky PDF
K okamžitému stažení
1240 Kč
Anglicky PDF Redline
K okamžitému stažení
1470 Kč
Anglicky Tisk
Skladem
1240 Kč
Označení normy:C1126-19
Vydáno:01.04.2019
Status:Active
Počet stran:6
Sekce:04.06
Označení:cellular phenolic thermal insulation; faced phenolic foam thermal insulation; phenolic foam thermal insulation; rigid thermal insulation; unfaced phenolic foam thermal insulation ;
Popis

1.1 This specification covers faced or unfaced, rigid cellular phenolic thermal insulation. Boards shall be faced or unfaced. Tubular forms and board cut from a block or bun covered by this standard shall be unfaced. It does not apply to field expanded cellular phenolic materials.

Note 1: If a facer or vapor retarder is to be used for the tubular form or board, then refer to Practice C921.

1.2 Materials covered by this specification are used as roof insulation; sheathing or rigid board for non-load bearing, building material applications; and pipe or board insulation cut from a block or bun for use between −40 and 257°F (−40 and 125°C). Type II and Type III materials with an appropriate vapor retarder covering on the warm surface are used to a lower temperature limit of −290°F (−180°C). (See 7.3.)

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4 This specification covers closed cell rigid cellular phenolic thermal insulation manufactured using blowing agents with an ozone depletion potential of 0 (ODP 0).

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

For specific precautionary statements, see Section 16.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.