BS 1881-210:2013
Testing hardened concrete Determination of the potential carbonation resistance of concrete. Accelerated carbonation method
Označení normy: | BS 1881-210:2013 |
Počet stran: | 22 |
Vydáno: | 2013-06-30 |
ISBN: | 978 0 580 78352 4 |
Status: | Standard |
BS 1881-210:2013
This standard BS 1881-210:2013 Testing hardened concrete is classified in these ICS categories:
- 91.100.30 Concrete and concrete products
ThispartofBS1881describesamethodforrankingthepotentialcarbonation resistanceofconcreteusinganacceleratedcarbonationtest.
NOTE 1 This test is an accelerated test because there is exposure to much higher than atmospheric levels of CO2 and is at a relative humidity conducive to a maximum rate of carbonation.
NOTE 2 The test under reference conditions takes a minimum of 112 days comprising a minimum age of the specimen prior to conditioning of 28 days, a minimum conditioning period of 14 days and a minimum exposure to increased CO2 levels of 70 days.
NOTE 3 The use of such test data in service-life modelling is still a matter of much academic debate and at present there is no consensus on an appropriate model.
Itisnotamethodforthedeterminationofcarbonationdepthsinexisting concretestructures.