sklademVydáno: 1992-12-15
BS 1894:1992 Specification for design and manufacture of electric boilers of welded construction

BS 1894:1992

Specification for design and manufacture of electric boilers of welded construction

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
10230 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
1023.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
3069.00 Kč
Anglicky Tisk
Skladem
10230 Kč
Označení normy:BS 1894:1992
Počet stran:100
Vydáno:1992-12-15
ISBN:0 580 21033 2
Status:Standard
Popis

BS 1894:1992


This standard BS 1894:1992 Specification for design and manufacture of electric boilers of welded construction is classified in these ICS categories:
  • 27.060.30 Boilers and heat exchangers

1.1.1 This British Standard specifies requirements for the design and manufacture, including materials, workmanship, inspection, testing, documentation and marking, of boilers utilizing electrical energy by the use of electrodes or immersion elements. The boilers dealt with are of cylindrical design, either horizontal or vertical, constructed from carbon or carbon manganese steels by fusion welding for which the limits of application are given in table 1.1.1.

Table 1.1.1. Limits of application
Classification Limit
Class I Steam and hot water boilers which exceed the limitations specified for class II and class III boilers
Class II Steam and hot water boilers the design pressure of which does not exceed 1.14 N/mm2 and the design pressure of which (in N/mm2), multiplied by the internal diameter in millimetres, does not exceed 1450
Class III

Steam boilers the design pressure of which does not exceed 0.23 N/mm2

Unvented hot water boilers the design pressure of which does not exceed 0.45 N/mm2

Vented hot water boilers the design pressure of which does not exceed 0.77 N/mm2

The standard applies to electric boilers which provide hot water, steam or superheated steam for use in industrial and commercial applications.

NOTE. Notwithstanding the materials quoted above this does not preclude the use of other materials, such as stainless steels or copper, copper linings, etc. (see 2.1) where the boiler otherwise falls within the limits of this specification, taking the allowable stresses from another appropriate specification.

1.1.2 In addition to the definitive requirements, this standard also requires the items detailed in 1.6 to be documented. For compliance with this standard, both the definitive requirements and the documented items have to be satisfied.


Includes materials, workmanship, inspection, testing, documentation and marking of boilers utilizing electrodes or immersion elements to provide hot water, steam or superheated steam. The boilers are of cylindrical design, constructed from carbon or carbon manganese steels by fusion welding.