Cena s DPH / bez DPH
Hlavní stránka>BS 2G 238:1996 Specification for electric cables for general airframe or equipment interconnect use (260°C), nickel plated copper and copper alloy conductors, with wrapped insulation
sklademVydáno: 1996-01-15
BS 2G 238:1996 Specification for electric cables for general airframe or equipment interconnect use (260°C), nickel plated copper and copper alloy conductors, with wrapped insulation

BS 2G 238:1996

Specification for electric cables for general airframe or equipment interconnect use (260°C), nickel plated copper and copper alloy conductors, with wrapped insulation

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4500 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
450.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1350.00 Kč
Anglicky Tisk
Skladem
4500 Kč
Označení normy:BS 2G 238:1996
Počet stran:22
Vydáno:1996-01-15
ISBN:0 580 24798 8
Status:Standard
Popis

BS 2G 238:1996


This standard BS 2G 238:1996 Specification for electric cables for general airframe or equipment interconnect use (260°C), nickel plated copper and copper alloy conductors, with wrapped insulation is classified in these ICS categories:
  • 49.060 Aerospace electric equipment and systems

This British Standard specifies the construction and performance requirements for a range of lightweight cables with wrapped insulation and nickel plated conductors suitable for general airframe use and for equipment interconnect use as stated below. The continuous current ratings for the cables are given in Annex A.

The following types of cable are specified:

00497867_img1

It is applicable to cables for use in the following situations.

  1. Cables for continuous use where the maximum stabilized conductor temperature does not exceed 260 °C and for applications involving flexing at temperatures down to − 65 °C;
  2. Cables for use where the potentials stated below do not exceed 600 V r.m.s and the frequency does not exceed 2 000 Hz:
    1. potential between conductors;
    2. potential between a conductor and screen;
    3. potential between a conductor and the aircraft structure;
  3. Interconnect cables for use in areas with some physical protection, such as behind panels or bulkheads. They also have an application for the internal wiring of equipment.
  4. Airframe cables of sufficiently robust construction for use for open aircraft wiring.

NOTE The latest edition of an Aerospace Series standard is indicated by a prefix number.