Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS 5446-4:2020 Fire detection and fire alarm devices for dwellings Specification for multi-sensor fire alarms using any combination of smoke, heat and carbon monoxide sensors
Sponsored link
sklademVydáno: 2020-11-27
BS 5446-4:2020 Fire detection and fire alarm devices for dwellings Specification for multi-sensor fire alarms using any combination of smoke, heat and carbon monoxide sensors

BS 5446-4:2020

Fire detection and fire alarm devices for dwellings Specification for multi-sensor fire alarms using any combination of smoke, heat and carbon monoxide sensors

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
10230 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
1023.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
3069.00 Kč
Anglicky Tisk
Skladem
10230 Kč
Označení normy:BS 5446-4:2020
Počet stran:132
Vydáno:2020-11-27
ISBN:978 0 539 05073 8
Status:Standard
Popis

BS 5446-4:2020


This standard BS 5446-4:2020 Fire detection and fire alarm devices for dwellings is classified in these ICS categories:
  • 13.220.20 Fire protection

This part of BS 5446 specifies requirements and type test methods for multi-sensor fire alarms, using one of the following combinations of sensors:

  1. smoke and heat;

  2. smoke and carbon monoxide;

  3. carbon monoxide and heat; and

  4. smoke, carbon monoxide and heat.

It is applicable to multi-sensor fire alarms intended solely for permanent installation on ceilings or walls of dwellings, and to multi-sensor fire alarms suitable for use in leisure accommodation vehicles (LAVs).

It is not applicable to multi-sensor fire alarms incorporating ionization smoke sensors.

NOTE 1 Equipment conforming to this part of BS 5446 might not be suitable for use in boats used as a means of accommodation on inland waterways, due to the corrosive atmosphere.

NOTE 2 Although not covered by this part of BS 5446, equipment is available for use with multi-sensor fire alarms to provide a suitable warning system for use by deaf and hard of hearing people (see BS 5446‑3).

NOTE 3 This part of BS 5446 does not cover the requirements for devices intended for incorporation in fire detection and alarm systems (see BS EN 54‑1).

NOTE 4 This part of BS 5446 does not include detection of carbon monoxide as a toxic gas (see BS EN 50291‑1).

NOTE 5 This part of BS 5446 does not include detection of fire using heat only (see BS 5446‑2).