Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS 5857-2.1:1980 Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of gas flow General
Sponsored link
sklademVydáno: 1980-03-31
BS 5857-2.1:1980 Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of gas flow General

BS 5857-2.1:1980

Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of gas flow General

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4898 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
489.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1469.40 Kč
Anglicky Tisk
Skladem
4898 Kč
Označení normy:BS 5857-2.1:1980
Počet stran:18
Vydáno:1980-03-31
ISBN:0 580 11246 2
Status:Standard
Popis

BS 5857-2.1:1980


This standard BS 5857-2.1:1980 Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of gas flow is classified in these ICS categories:
  • 17.120.10 Flow in closed conduits

This International Standard deals with the measurement of gas flow in conduits by using tracer methods.

In a steady flow of compressible fluid, the only conservative parameter is the mass rate of flow qm. Therefore the whole of this International Standard will refer to mass rate of flow qm.

However, for those fluids for which the composition (and therefore, the mass density) may not be known accurately, the volume rate of flow qv could be measured, it being understood that this volume rate of flow is only valid for the conditions of temperature and pressure at which it has been measured.

This International Standard applies to flow measurement in conduits into which a tracer can be injected in such a way that effective mixing in single phase with the gas flowing in the pipe can be achieved.

The fluid in the conduit can be a mixture of several gases provided the thermodynamic state and conditions of flow of this mixture are well defined.

Two fundamental test procedures are used:

  • — The first, known as the constant rate injection method, is based on the dilution principle: a tracer solution is injected into the conduit and the dilution (ratio) of this tracer in the gas flowing in the conduit is determined, this dilution being proportional to the rate of flow.
  • — The second is a method of measurement of the transit time (formerly called Allen velocity method): the tracer is injected into the conduit and the time taken by the tracer to travel a specified length between two cross-sections in each of which it is detected, is measured.

The advantages and disadvantages of these two methods are considered in clause 4. The distance between injection and measuring sections shall be sufficient to achieve mixing of the tracer with the gas flowing in the conduit according to the methods; the adequate mixing distance is considered in clause 6.

A large number of different tracers may be used, such as radioactive or non-radioactive, mineral or organic materials. The choice of tracer depends on the circumstances of the measurement (see clause 5). The uncertainty of the measurements may be less than 1 % under good conditions (see clause 7).


Compares the dilution method with the method based on transit time measurement. Also covers choice of tracers and measuring/mixing lengths.