Cena s DPH / bez DPH
Hlavní stránka>BS 6068-2.37:1990 Water quality. Physical, chemical and biochemical methods Method for the determination of chloride via a silver nitrate titration with chromate indicator (Mohr's method)
Sponsored link
sklademVydáno: 1990-09-30
BS 6068-2.37:1990 Water quality. Physical, chemical and biochemical methods Method for the determination of chloride via a silver nitrate titration with chromate indicator (Mohr's method)

BS 6068-2.37:1990

Water quality. Physical, chemical and biochemical methods Method for the determination of chloride via a silver nitrate titration with chromate indicator (Mohr's method)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
3906 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
390.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1171.80 Kč
Anglicky Tisk
Skladem
3906 Kč
Označení normy:BS 6068-2.37:1990
Počet stran:12
Vydáno:1990-09-30
ISBN:0 580 18754 3
Status:Standard
Popis

BS 6068-2.37:1990


This standard BS 6068-2.37:1990 Water quality. Physical, chemical and biochemical methods is classified in these ICS categories:
  • 13.040.01 Air quality in general

1.1 Application range

This International Standard specifies a titration method for the determination of dissolved chloride in water. The method is applicable to the direct determination of dissolved chloride in concentrations between 5 mg/l and 150 mg/l. The working range may be extended to 400 mg/l by using a burette of larger capacity or by sample dilution. Due to many interferences the method is not applicable to heavily polluted waters of low chloride content.

1.2 Interferences

Normal concentrations of common constituents of ground water, surface water and potable water do not interfere with the determination.

The following substances interfere with the method

  • Substances forming insoluble silver compounds, such as bromides, iodides, sulfides, cyanides, hexacyanoferrates(II) and hexacyanoferrates(III). If necessary, bromide and iodide ions shall be determined separately, and the result of the chloride determination corrected accordingly.
  • Compounds forming complexes with silver ions, such as ammonium and thiosulfate ions.
  • Compounds which will reduce chromate ions, including iron(II) and sulfite ions.

The interferences mentioned above will lead to high chloride values.

Highly coloured or turbid solutions may obscure the end point, for example hydrated iron oxide.


Applicable to waters that are not heavily polluted and of low chloride content. For chloride concentrations from 5 mg/l to 150 mg/l.