Hlavní stránka>BS 6068-2.41:1993 Water quality. Physical, chemical and biochemical methods Determination of fluoride: electrochemical probe method for potable and lightly polluted water
Sponsored link
sklademVydáno: 1993-03-15
BS 6068-2.41:1993 Water quality. Physical, chemical and biochemical methods Determination of fluoride: electrochemical probe method for potable and lightly polluted water

BS 6068-2.41:1993

Water quality. Physical, chemical and biochemical methods Determination of fluoride: electrochemical probe method for potable and lightly polluted water

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4154 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
415.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1246.20 Kč
Anglicky Tisk
Skladem
4154 Kč
Označení normy:BS 6068-2.41:1993
Počet stran:14
Vydáno:1993-03-15
ISBN:0 580 21643 8
Status:Standard
Popis

BS 6068-2.41:1993


This standard BS 6068-2.41:1993 Water quality. Physical, chemical and biochemical methods is classified in these ICS categories:
  • 13.060.50 Examination of water for chemical substances

1.1 Field of application

This part of ISO 10359 specifies a method for the determination of dissolved fluoride in fresh, potable and low contaminated water, and some surface waters, using an electrochemical technique.

The method is directly suitable for measuring fluoride concentrations from 0,2 mg/l to 2,0 g/l. After the addition of a known amount of fluoride, concentrations as low as 0,02 mg/l can be detected (see 7.3).

The method is not suitable for waste waters and industrial effluents; this determination will be the subject of ISO 10359-2.

1.2 Interferences

The electrode will respond directly to hydroxide ions. The formation of HF under acidic conditions will reduce the measured fluoride concentration. Therefore, buffer all test aliquots to a pH between 5 and 7 to prevent such interference. Cations such as calcium, magnesium, iron and aluminium form complexes with fluoride or precipitates to which the electrode does not respond. Therefore the buffer solution also contains trans-1,2-diaminocyclohexane-N,N,Nʹ,Nʹ-tetraacetic acid (CDTA) as a decomplexing agent to free bound fluoride. The boron tetrafluoride anion, BF4, is not decomplexed by the addition of buffer.


Applicable to fluoride concentrations from 0,02 mg/l to 2,0 g/l.