BS 6230:2011 Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd and 3rd family gases)

BS 6230:2011

Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd and 3rd family gases)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7808 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
780.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2342.40 Kč
Anglicky Tisk
Skladem
7808 Kč
Označení normy:BS 6230:2011
Počet stran:42
Vydáno:2011-07-31
ISBN:978 0 580 71929 5
Status:Standard
Popis

BS 6230:2011


This standard BS 6230:2011 Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd and 3rd family gases) is classified in these ICS categories:
  • 97.100.20 Gas heaters

This British Standard specifies the installation requirements for direct and indirect gas-fired forced convection air heaters for space heating that are designed for commercial or industrial applications and to which The Gas Appliances (Safety) Regulations 1995 [1] apply.

This British Standard applies to the installation and maintenance of appliances that are designed to utilize gases of Group H of the 2nd family (e.g. natural gas), gases of Group P of the 3rd family (e.g. propane) as well as gases of Group B of the 3rd family (e.g. butane) when supplied under the conditions of the third family pressure couple (see BS EN 437:2003+A1:2009).

NOTE 1 This British Standard does not specifically cover LPG/air for which additional requirements might be necessary.

This British Standard applies to the installation of direct gas-fired air heaters within the scope of BS EN 525:2009 and to indirect gas-fired forced convection air heaters within the scope of BS EN 621:2009, BS EN 1020:2009 and, where appropriate, BS EN 1196:1998. These standards cover air heaters having a net heat input not exceeding 300 kW. This standard also applies to the installation of direct gas-fired air heaters within the scope of BS 5990:2006 and to indirect gas-fired forced convection air heaters within the scope of BS 5991:1998. These standards cover air heaters having a gross heat input greater than 330 kW but not exceeding 2 MW (1.8 MW net).

NOTE 2 For the purposes of this British Standard, installation includes design, inspection and commissioning. It is recognized that each of the tasks can be performed at the same time by different persons.

NOTE 3 The ratio of gross to net heat input is approximately 1.11:1 for Group H (natural gas), 1.09:1 for Group P (propane) and 1.08:1 for Group B (butane).

NOTE 4 The ventilation rates in cm2/kW of heat input given in this British Standard are based on the net calorific value.

This British Standard also applies to air heaters designed to supply make-up air, door curtain heaters, transportable air heaters and heat exchange modules (i.e. air heaters without a main air movement fan) where such heat exchange modules are used in environmental non-process applications such as air handling units. It also covers installation of heaters in areas where petroleum or other flammable heavier-than-air vapours can be present (see 5.1.2).

It does not include the safety requirements for installation where flammable dusts, toxic gases or flammable lighter-than-air gases might be present in significant quantities.

NOTE 5 In such cases it is important that liaison takes place with the Health and Safety Executive.

This British Standard does not apply to the installation of air heaters to which The Gas Appliances (Safety) Regulations 1995 [1] apply, or that are designed for the sole use in domestic premises.