BS 7346-4:2003 Components for smoke and heat control systems Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing steady-state design fires. Code of practice

BS 7346-4:2003

Components for smoke and heat control systems Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing steady-state design fires. Code of practice

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9420 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
942.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2826.00 Kč
Anglicky Tisk
Skladem
9420 Kč
Označení normy:BS 7346-4:2003
Počet stran:90
Vydáno:2003-08-23
ISBN:0 580 42233 X
Status:Standard
Popis

BS 7346-4:2003


This standard BS 7346-4:2003 Components for smoke and heat control systems is classified in these ICS categories:
  • 13.220.20 Fire protection

This part of BS 7346 gives recommendations and guidance on functional and calculation methods for smoke and heat exhaust ventilation systems for steady-state design fires. It is intended for a variety of building types and applications, including single-storey buildings, mezzanine floors, warehouses with palletized or racked storage, shopping malls, atria and complex buildings, car parks, places of entertainment and public assembly and uncompartmented space within multi-storey buildings.

This standard does not include any functional recommendations for design parameters where the primary purpose of the SHEVS is to assist fire-fighting.

NOTE Such functional recommendations need to be agreed with the fire service responsible for the building in question. The calculation procedures set out in the annexes of this document can be used to design the SHEVS to meet whatever recommendations have been agreed.

This standard does not cover the following:

  • smoke clearance, where smoke is exhausted from a building after the fire has been suppressed;

  • cross-ventilation, where wind-induced or fan-induced air currents sweep smoke through and out of the building, usually as part of fire-fighting operational procedures;

  • ventilation of stairwells, which usually represents a special application of smoke clearance and which does not necessarily protect the continued use of the stairwell;

  • fully-involved fires.