Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS 759-1:1984 Valves, gauges and other safety fittings for application to boilers and to piping installations for and in connection with boilers Specification for valves, mountings and fittings
Sponsored link
sklademVydáno: 1984-02-29
BS 759-1:1984 Valves, gauges and other safety fittings for application to boilers and to piping installations for and in connection with boilers Specification for valves, mountings and fittings

BS 759-1:1984

Valves, gauges and other safety fittings for application to boilers and to piping installations for and in connection with boilers Specification for valves, mountings and fittings

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4898 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
489.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1469.40 Kč
Anglicky Tisk
Skladem
4898 Kč
Označení normy:BS 759-1:1984
Počet stran:20
Vydáno:1984-02-29
ISBN:0 580 13646 9
Status:Standard
Popis

BS 759-1:1984


This standard BS 759-1:1984 Valves, gauges and other safety fittings for application to boilers and to piping installations for and in connection with boilers is classified in these ICS categories:
  • 27.060.01 Burners and boilers in general

This Part of this British Standard specifies requirements for steam and water fittings excluding safety valves for boiler installations where the steam pressure exceeds 1 bar gauge or, in the case of hot water boilers, the rating is 44 kW and above. It also specifies requirements for fittings for boilers used exclusively for the following:

  1. low pressure steam heating in which the whole of the condensate is returned to the boiler on a closed circuit;

  2. hot water central heating;

  3. hot water supply.

It deals with valves, boiler blowdown mountings, water level gauges, high and low water level alarms, pressure gauges, test connections and fusible plugs. Where appropriate, general recommendations relating to the installation of fittings are included for the guidance of users. Additional requirements specific to steam and hot water boilers, arranged for automatic working, are given in section 5.

This Part does not cover fittings for boilers used in open vented hot water systems working at temperatures not exceeding 100 °C nor for storage water heaters of the unvented type which normally operate at temperatures not exceeding 82 °C and at pressures not exceeding 10 bar1). For such boilers within the scope of BS 779 and BS 855 the requirements are incorporated in those standards.

NOTE The titles of the publications referred to in this standard are listed on the inside back cover.


Specifies requirements for safety fittings excluding safety valves for boiler installations where the steam pressure exceeds 1 bar gauge or, in the case of hot water boilers, the rating is 44 kW and above.