Hlavní stránka>BS 8414-2:2020 Fire performance of external cladding systems Test method for non-loadbearing external cladding systems fixed to, and supported by, a structural steel frame
Sponsored link
sklademVydáno: 2020-04-29
BS 8414-2:2020 Fire performance of external cladding systems Test method for non-loadbearing external cladding systems fixed to, and supported by, a structural steel frame

BS 8414-2:2020

Fire performance of external cladding systems Test method for non-loadbearing external cladding systems fixed to, and supported by, a structural steel frame

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6820 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
682.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2046.00 Kč
Anglicky Tisk
Skladem
6820 Kč
Označení normy:BS 8414-2:2020
Počet stran:24
Vydáno:2020-04-29
ISBN:978 0 539 04608 3
Status:Standard
Popis

BS 8414-2:2020


This standard BS 8414-2:2020 Fire performance of external cladding systems is classified in these ICS categories:
  • 13.220.50 Fire-resistance of building materials and elements

This part of BS 8414 provides a test method for determining the fire performance characteristics of non‑loadbearing external cladding systems when fixed to, and supported by, a structural steel frame and exposed to an external fire under controlled conditions. The peak fire exposure is intended to be representative of an external fire source or a fully developed (post-flashover) fire in a room venting from an aperture that exposes the cladding to the effects of external flames.

This part of BS 8414 is solely intended to give an indication of fire spread across or within an external cladding system. The purpose of the test is to provide data to enable evaluation of the fire performance of the components when combined to form a complete cladding system.

This part of BS 8414 does not apply to non‑loadbearing external rainscreen overcladding systems or external wall insulation systems applied to the face of a building, the fire testing of which is covered in BS 8414‑1.

This part of BS 8414 does not cover the performance of glass or its supporting frame intended for glazed window openings.

This part of BS 8414 does not apply to glazed curtain walling systems.

This part of BS 8414 does not test the total configuration of a construction incorporating additional windows, doors, balconies or ancillary penetrations.

This part of BS 8414 does not cover exposure to radiant heat from a fire in an adjacent building.

NOTE 1 Performance criteria and classification methodology for the external fire performance can be found in references such as Report BR 135 [2].

NOTE 2 Further information on the application of results from BS 8414‑2 is given in BS 9414.