BS 8519:2020 Selection and installation of fire-resistant power and control cable systems for life safety, fire-fighting and other critical applications. Code of practice

BS 8519:2020

Selection and installation of fire-resistant power and control cable systems for life safety, fire-fighting and other critical applications. Code of practice

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8556 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
855.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2566.80 Kč
Anglicky Tisk
Skladem
8556 Kč
Označení normy:BS 8519:2020
Počet stran:48
Vydáno:2020-06-25
ISBN:978 0 539 00951 4
Status:Standard
Popis

BS 8519:2020


This standard BS 8519:2020 Selection and installation of fire-resistant power and control cable systems for life safety, fire-fighting and other critical applications. Code of practice is classified in these ICS categories:
  • 29.060.01 Electrical wires and cables in general
  • 13.220.20 Fire protection

This British Standard gives recommendations and guidance on the selection and installation of fire-resistant power and control cable systems which need to maintain their circuit integrity for life safety and fire-fighting. It also gives specific recommendations for electrical system design for such applications, and for fire survival times.

This British Standard is primarily intended for use in buildings which, due to their size, height, form or use, require the installation of life safety and fire-fighting systems, e.g. sprinkler pumps, wet riser pumps, smoke control systems, fire-fighting and evacuation lifts or other systems as required by the fire engineered strategy.

It covers:

  • the source of supply;

  • the distribution voltage [high voltage (HV) or low voltage (LV)]; and

  • the appropriate location of the main intake rooms, HV switchrooms, LV switchrooms, transformer rooms, generator rooms, risers, fire life safety equipment plant rooms and fire‑fighting/evacuation lift motor rooms/shafts.

The British Standard can also be used for systems which need to maintain their circuit integrity during a fire because the function they support is critical for business continuity, property protection or environmental protection reasons.

This British Standard does not give recommendations for those installations covered in BS 5839‑1, BS 5839‑8, BS 5839‑9 and BS 5266‑1, but makes reference to these standards.