Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS 8562:2011 Gas cylinders. In situ, non-destructive examination and testing of refillable seamless steel tubes of water capacity between 150 L and 3000 L, used for compressed gases Specification
Sponsored link
sklademVydáno: 2011-03-31
BS 8562:2011 Gas cylinders. In situ, non-destructive examination and testing of refillable seamless steel tubes of water capacity between 150 L and 3000 L, used for compressed gases Specification

BS 8562:2011

Gas cylinders. In situ, non-destructive examination and testing of refillable seamless steel tubes of water capacity between 150 L and 3000 L, used for compressed gases Specification

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4898 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
489.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1469.40 Kč
Anglicky Tisk
Skladem
4898 Kč
Označení normy:BS 8562:2011
Počet stran:20
Vydáno:2011-03-31
ISBN:978 0 580 73748 0
Status:Standard
Popis

BS 8562:2011


This standard BS 8562:2011 Gas cylinders. In situ, non-destructive examination and testing of refillable seamless steel tubes of water capacity between 150 L and 3000 L, used for compressed gases Specification is classified in these ICS categories:
  • 23.020.35 Gas cylinders

This British Standard specifies requirements for using a combination of appropriate in situ, Non-Destructive Examination (NDE) techniques [e.g. visual examination, Acoustic emission Testing (AT) and Ultrasonic Examination (UE)] when periodically inspecting and testing tubes of seamless steel construction and water capacity between 150 L and 3000 L, used for compressed gases for a further period of service.

This British Standard is applicable only to tubes installed in locations where attempting any removal from their containing superstructure would be hazardous or impossible (e.g. offshore oil installations), or where the downtime required to remove the tube would hinder safe operation of a plant or service (e.g. power generation, hospitals, advanced research applications and marine installations such as heave compensation systems on semi-submersible drilling rigs).

Indication of any anomaly in the tube(s) under test that are revealed at the time of in situ inspection have to be evaluated using a different technique to be able to quantify (location and frequency) and size any possible imperfection.