Cena s DPH / bez DPH
Hlavní stránka>BS EN 12309-3:2024 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Requirements, test conditions and test methods
sklademVydáno: 2024-05-17
BS EN 12309-3:2024 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Requirements, test conditions and test methods

BS EN 12309-3:2024

Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Requirements, test conditions and test methods

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9420 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
942.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2826.00 Kč
Anglicky Tisk
Skladem
9420 Kč
Označení normy:BS EN 12309-3:2024
Počet stran:80
Vydáno:2024-05-17
ISBN:978 0 539 20824 5
Status:Standard
Popis

BS EN 12309-3:2024


This standard BS EN 12309-3:2024 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW is classified in these ICS categories:
  • 27.080 Heat pumps
  • 91.140.30 Ventilation and air-conditioning systems
1.1 Scope of EN 12309 series Appliances covered by this document include one or a combination of the following: - gas-fired sorption chiller; - gas-fired sorption chiller/heater; - gas-fired sorption heat pump; - hybrids based on gas sorption appliances. This document applies to appliances designed to be used for space heating or cooling or refrigeration with or without heat recovery. This document applies to appliances having flue gas systems of Type B and Type C (according to EN 1749:2020) and to appliances designed for outdoor installations, including Type A. EN 12309 does not apply to air conditioners, it only applies to appliances having: - integral burners under the control of fully automatic burner control systems; - closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated; - mechanical means to assist transportation of the combustion air and/or the flue gas. The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in EN 12309-1:2023). In the case of packaged units (consisting of several parts), this document applies only to those designed and supplied as a complete package. The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309. Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309. All the symbols given in this text are to be used regardless of the language used. 1.2 Scope of this Part 3 of EN 12309 This part of EN 12309 specifies the requirements, test methods and conditions for gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW. This part of EN 12309 deals particularly with test protocols and tools to calculate the capacity, the gas utilization efficiency and the electrical power input of the appliance. This data can be used in particular to calculate the seasonal efficiency of the appliance.