Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN 1364-4:2014 Fire resistance tests for non-loadbearing elements Curtain walling. Part configuration
Sponsored link
sklademVydáno: 2014-06-30
BS EN 1364-4:2014 Fire resistance tests for non-loadbearing elements Curtain walling. Part configuration

BS EN 1364-4:2014

Fire resistance tests for non-loadbearing elements Curtain walling. Part configuration

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9486 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
948.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2845.80 Kč
Anglicky Tisk
Skladem
9486 Kč
Označení normy:BS EN 1364-4:2014
Počet stran:64
Vydáno:2014-06-30
ISBN:978 0 580 86415 5
Status:Standard
Popis

BS EN 1364-4:2014


This standard BS EN 1364-4:2014 Fire resistance tests for non-loadbearing elements is classified in these ICS categories:
  • 91.060.10 Walls. Partitions. Façades
  • 13.220.50 Fire-resistance of building materials and elements

This European Standard specifies a method for determining the fire resistance of parts of curtain walling and of the perimeter seal. It examines the fire resistance to internal and external fire exposure of:

  • the spandrel panel, i.e. downstand, upstand or a combination thereof, or

  • the perimeter seal, or

  • the fixing of the framing system (anchoring) used to attach the curtain walling to the floor element, or

  • combinations thereof.

Results from tests according to this standard form the basis for classification of curtain walling type A (see 3.3 for definition).

For curtain walling type B (see 3.4 for definition) results may be used to determine fire resistance of parts of a curtain walling to increase the field of application when previously tested to EN 1364-3. For intended classification EW and for corner/faceted specimens EN 1364-3 should be used.

This European Standard does not cover double skin façades, over-cladding systems and ventilated façade systems on external walls. It does not deal with the reaction to fire behaviour of curtain walling.

This standard is intended to be read in conjunction with EN 1363-1 and EN 1363-2 as well as EN 1364-3 for curtain walling type B.

NOTE Annex A gives informative guidance on the principles of testing parts of curtain walling and the test method.