Cena s DPH / bez DPH
Hlavní stránka>BS EN 14662-1:2023 Ambient air quality. Standard method for measurement of benzene concentrations Pumped sampling followed by thermal desorption and gas chromatography
Sponsored link
sklademVydáno: 2024-01-03
BS EN 14662-1:2023 Ambient air quality. Standard method for measurement of benzene concentrations Pumped sampling followed by thermal desorption and gas chromatography

BS EN 14662-1:2023

Ambient air quality. Standard method for measurement of benzene concentrations Pumped sampling followed by thermal desorption and gas chromatography

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9734 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
973.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2920.20 Kč
Anglicky Tisk
Skladem
9734 Kč
Označení normy:BS EN 14662-1:2023
Počet stran:76
Vydáno:2024-01-03
ISBN:978 0 539 20982 2
Status:Standard
Popis

BS EN 14662-1:2023


This standard BS EN 14662-1:2023 Ambient air quality. Standard method for measurement of benzene concentrations is classified in these ICS categories:
  • 13.040.20 Ambient atmospheres
This document gives general guidance for the sampling and analysis of benzene in air by pumped sampling, thermal desorption and capillary gas chromatography. This document is in accordance with the generic methodology selected as the basis of the European Union reference method for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period. This document is valid for the measurement of benzene in a concentration range of approximately 0,5 μg/m3 to 50 μg/m3. Air samples are typically collected over periods ranging from a few hours to 7 days. The upper limit of the useful range is set by the sorptive capacity (the safe sampling volume) of the sorbent and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capacity of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sorbent. Artefacts are typically sub ng for graphitised carbon sorbents, but higher levels of aromatic hydrocarbons have been noted in other sorbents - e.g. porous polymers. The detection limit will be approximately 1/10 of the lower concentration range. This document provides general guidance for the sampling of benzene using either a single sampler, which is changed manually after every exposure period, or a multi-sampler capable of storing and exposing multiple samples without user intervention.