Cena s DPH / bez DPH
Hlavní stránka>BS EN 14662-3:2015 Ambient air. Standard method for the measurement of benzene concentrations Automated pumped sampling with in situ gas chromatography
Sponsored link
sklademVydáno: 2015-11-30
BS EN 14662-3:2015 Ambient air. Standard method for the measurement of benzene concentrations Automated pumped sampling with in situ gas chromatography

BS EN 14662-3:2015

Ambient air. Standard method for the measurement of benzene concentrations Automated pumped sampling with in situ gas chromatography

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9734 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
973.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2920.20 Kč
Anglicky Tisk
Skladem
9734 Kč
Označení normy:BS EN 14662-3:2015
Počet stran:76
Vydáno:2015-11-30
ISBN:978 0 580 80852 4
Status:Standard
Popis

BS EN 14662-3:2015


This standard BS EN 14662-3:2015 Ambient air. Standard method for the measurement of benzene concentrations is classified in these ICS categories:
  • 13.040.20 Ambient atmospheres

This European Standard specifies a semi-continuous measurement method for the determination of the concentration of benzene present in ambient air based on automated sampling and analysis by gas chromatography. This European Standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate automated gas chromatograph (GC) by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.

The method is applicable to the determination of the mass concentration of benzene present in ambient air in the range up to 50 μg/m3 benzene. This concentration range represents the certification range for the type approval test.

Other ranges may be used depending on the levels present in ambient air.

NOTE 1 When the standard is used for other purposes than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.

The method covers the determination of ambient air concentrations of benzene in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources.

The results are expressed in μg/m3 (at 20 °C and 101,3 kPa).

NOTE 2 50 μg/m3 of benzene corresponds to 15,4 nmol/mol of benzene.

This European Standard contains information for different groups of users.

Clauses 5 to 7 and Annexes C and D contain general information about the principles of benzene measurement by automated gas chromatography and sampling equipment.

Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of benzene analysers. These sections contain information about:

  • type-approval test conditions, test procedures and test requirements;

  • analyser performance requirements;

  • evaluation of the type-approval test results;

  • evaluation of the uncertainty of the measurement results of the benzene analyser based on the type-approval test results.

Clauses 9 to 11 and Annex F are directed towards monitoring networks performing the practical measurements of benzene in ambient air. These sections contain information about:

  • initial installation of the analyser in the monitoring network and acceptance testing;

  • ongoing quality assurance/quality control;

  • calculation and reporting of measurement results;

  • evaluation of the uncertainty of measurement results under practical monitoring conditions.