Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN 1473:2021 - TC Tracked Changes. Installation and equipment for liquefied natural gas. Design of onshore installations
Sponsored link
sklademVydáno: 2021-11-12
BS EN 1473:2021 - TC Tracked Changes. Installation and equipment for liquefied natural gas. Design of onshore installations

BS EN 1473:2021 - TC

Tracked Changes. Installation and equipment for liquefied natural gas. Design of onshore installations

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
14322 Kč
Anglicky Tisk
Skladem
14322 Kč
Označení normy:BS EN 1473:2021 - TC
Počet stran:364
Vydáno:2021-11-12
ISBN:978 0 539 19924 6
Status:Tracked Changes
Popis

BS EN 1473:2021 - TC


This standard BS EN 1473:2021 - TC Tracked Changes. Installation and equipment for liquefied natural gas. Design of onshore installations is classified in these ICS categories:
  • 75.200 Petroleum products and natural gas handling equipment

This document gives guidelines for the design, construction and operation of all onshore liquefied natural gas (LNG) installations for the liquefaction, storage, vaporization, transfer and handling of LNG and natural gas (NG).

This document is applicable for plants with an LNG storage capacity above 200 t.

The designated boundary limits are LNG inlet/outlet by the ship’s manifold including vapour return connection, the truck loading/unloading connection including vapour return, the rail car loading/unloading connection including vapour return and the natural gas in and outlet boundary by piping systems.

Terminals or plant types have one or more boundary limits as described in this scope (see Figure 1).

A short description of each of these installations is given in Annex G.

Feed gas for LNG liquefaction installations (plant) can be from gas field, associated gas from oil field, piped gas from transportation grid or from renewables.

Floating solutions (for example FPSO, FSRU, SRV), whether off-shore or near-shore, are not covered by this document even if some concepts, principles or recommendations could be applied. However, in case of berthed FSRU with LNG transfer across the jetty, the following recommendations apply for the jetty and topside facilities.

In case of solutions using floating storage unit (FSU) and land-based re-gasification solution, the on-shore part is covered by these standard recommendations.

Plants with a storage inventory from 5 t up to 200 t are covered by [5].