Cena s DPH / bez DPH
Hlavní stránka>BS EN 14792:2017 Stationary source emissions. Determination of mass concentration of nitrogen oxides. Standard reference method. Chemiluminescence
sklademVydáno: 2017-01-31
BS EN 14792:2017 Stationary source emissions. Determination of mass concentration of nitrogen oxides. Standard reference method. Chemiluminescence

BS EN 14792:2017

Stationary source emissions. Determination of mass concentration of nitrogen oxides. Standard reference method. Chemiluminescence

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8700 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
870.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2610.00 Kč
Anglicky Tisk
Skladem
8700 Kč
Označení normy:BS EN 14792:2017
Počet stran:60
Vydáno:2017-01-31
ISBN:978 0 580 85051 6
Status:Standard
Popis

BS EN 14792:2017


This standard BS EN 14792:2017 Stationary source emissions. Determination of mass concentration of nitrogen oxides. Standard reference method. Chemiluminescence is classified in these ICS categories:
  • 13.040.40 Stationary source emissions

This European Standard specifies the standard reference method (SRM) based on the chemiluminescence principle for the determination of the nitrogen oxides (NO x) in flue gases emitted to the atmosphere from ducts and stacks. It includes the sampling and the gas conditioning system, as well as the analyser.

This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by portable automated measuring systems (P-AMS) based on this measurement method. It applies for periodic monitoring and for the calibration or control of automated measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes.

This European Standard specifies criteria for demonstration of equivalence of an alternative method to the SRM by application of EN 14793:2017 .

This European Standard has been validated during field tests on waste incineration, co-incineration and large combustion installations and on a recognized test-bench. It has been validated for sampling periods of 30 min in the range of 0 mg/m 3 to 1 300 mg/m 3 of Nox for large combustion plants and 0 mg/m 3 to 400 mg/m 3 of NO x for waste incineration, according to emission limit values (ELV) laid down in the Directive 2010/75/EU .

The ELV for NO x (NO + NO 2) in EU Directives is expressed in mg/m 3 of NO 2 on a dry basis, at a specified value for oxygen and at standard conditions (273 K and 101,3 kPa).

NOTE

The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in Annex A.