Cena s DPH / bez DPH
Hlavní stránka>BS EN 15182-1:2019 Portable equipment for projecting extinguishing agents supplied by firefighting pumps. Hand-held branchpipes for fire service use Common requirements
Sponsored link
sklademVydáno: 2019-09-27
BS EN 15182-1:2019 Portable equipment for projecting extinguishing agents supplied by firefighting pumps. Hand-held branchpipes for fire service use Common requirements

BS EN 15182-1:2019

Portable equipment for projecting extinguishing agents supplied by firefighting pumps. Hand-held branchpipes for fire service use Common requirements

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6448 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
644.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1934.40 Kč
Anglicky Tisk
Skladem
6448 Kč
Označení normy:BS EN 15182-1:2019
Počet stran:32
Vydáno:2019-09-27
ISBN:978 0 580 99377 0
Status:Standard
Popis

BS EN 15182-1:2019


This standard BS EN 15182-1:2019 Portable equipment for projecting extinguishing agents supplied by firefighting pumps. Hand-held branchpipes for fire service use is classified in these ICS categories:
  • 13.220.10 Fire-fighting

This document applies to hand-held branchpipes. It deals with:

  • safety requirements;

  • performance requirements;

  • test methods;

  • classification and designation;

  • instructions for use and maintenance;

  • marking.

It is advised to read this document in conjunction with parts 2, 3 or 4.

This document does not apply to branchpipes covered by EN� 671 series, foam branchpipes covered by EN� 16712â??3, powder branchpipes, or branchpipes with a maximum working pressure above 40� bar.

NOTE� 1

The Working Group has thoroughly addressed and discussed the issue of electrical safety in relation to using water branchpipes. However, an electrical test is not incorporated into this document as international experience, as well as research (NFPA handbook, French research, etc) have shown that any â??artificialâ?? or â??laboratory styleâ?? testing will not take into account poor visibility and other conditions present on any fire ground, nor the problem of estimating distances under these conditions. When fighting fires in or near electrical installations, the power is cut off as soon as possible (see the operating instructions, 8.1). Also, it is best practice to maintain a maximum possible safety distance (at least 1� m up to 1� 000� V) and to use a spray jet with a minimum spray angle of 30 �°.

NOTE� 2

It is essential to take into account reaction forces before choosing and operating branchpipes.