Hlavní stránka>BS EN 15423:2008 Ventilation for buildings. Fire precaution for air distribution systems in buildings
sklademVydáno: 2008-11-30
BS EN 15423:2008 Ventilation for buildings. Fire precaution for air distribution systems in buildings

BS EN 15423:2008

Ventilation for buildings. Fire precaution for air distribution systems in buildings

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6240 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
624.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1872.00 Kč
Anglicky Tisk
Skladem
6240 Kč
Označení normy:BS EN 15423:2008
Počet stran:28
Vydáno:2008-11-30
ISBN:978 0 580 56171 9
Status:Standard
Popis

BS EN 15423:2008


This standard BS EN 15423:2008 Ventilation for buildings. Fire precaution for air distribution systems in buildings is classified in these ICS categories:
  • 13.220.50 Fire-resistance of building materials and elements
  • 91.140.30 Ventilation and air-conditioning systems
This document gives guidance for system designers, installers, commissioners and maintenance teams on the incorporation of protective measures for air distribution systems including dual purpose systems for smoke and heat exhaust systems within buildings, to prevent the initiation and the spread of fire, smoke and other by-products of combustion. This document intends to only support any national (building) regulations, which are the basis of any design of a building or parts of it. It is up to the designer to enquire about the suitability (in particular in legal terms) of a specific solution given in this document (e.g. although "dual purpose systems" are covered in this document, they may not be permitted in some Member States or only in certain types of buildings). This document applies to all air distribution systems including dual purpose systems (except systems only dedicated to smoke exhaust systems, which are dealt in other European standards) including technical rooms or spaces for the installation of devices to assist in ventilation of a building (e.g. distance of storage of combustible materials to devices and not the fire resistance of the building structure), penetrations, and following components/products used in the system like: - inlet/outlet louvres; - fans not exposed / exposed to the smoke; - air control dampers; - ducts; - fire control dampers; - air terminal devices; - anchors and supports; - duct fittings; - control panels; - cables and connections; - air handling units; - air filters; - sound attenuators; - heat exchangers.