Cena s DPH / bez DPH
Hlavní stránka>BS EN 15446:2008 Fugitive and diffuse emissions of common concern to industry sectors. Measurement of fugitive emission of vapours generating from equipment and piping leaks
sklademVydáno: 2008-09-30
BS EN 15446:2008 Fugitive and diffuse emissions of common concern to industry sectors. Measurement of fugitive emission of vapours generating from equipment and piping leaks

BS EN 15446:2008

Fugitive and diffuse emissions of common concern to industry sectors. Measurement of fugitive emission of vapours generating from equipment and piping leaks

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4500 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
450.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1350.00 Kč
Anglicky Tisk
Skladem
4500 Kč
Označení normy:BS EN 15446:2008
Počet stran:20
Vydáno:2008-09-30
ISBN:978 0 580 56280 8
Status:Standard
Popis

BS EN 15446:2008


This standard BS EN 15446:2008 Fugitive and diffuse emissions of common concern to industry sectors. Measurement of fugitive emission of vapours generating from equipment and piping leaks is classified in these ICS categories:
  • 13.040.40 Stationary source emissions
This standard applies to the measurement of fugitive emissions of volatile organic compounds (VOCs) from process equipment. The leak sources include, but are not limited to, valves, flanges and other connections, pressure relief devices, process drains, open-ended valves, pump and compressor seal systems, agitator seals, and access door seals. It does not apply to instrument tubing connections. This standard applies to all products of which at least 20 % wt has a vapour pressure higher than 0,3 kPa at 20 °C. For the petroleum industry, this includes all light products and excludes kerosene and all heavier products. The standard is based on the measurement of the gas concentration at the interface of a leak. This concentration is measured with a portable instrument. It is converted to a mass emission rate by use of a set of correlations. The scope of this standard includes the complete data processing, from the initial concentration measurement up to the generation of an emission report over a reporting period (which is generally one year) ). This standard does not prescribe the number of potential emission points that should be screened each year nor the frequency at which these points should be screened. This sampling strategy shall indeed take into account the plant characteristics and the required level of control over fugitive emissions. Optical methods are currently under development to ease the detection of leaks in plants and use of this standard in conjunction with these methods might be possible. In any case, measurements have to be performed according to the requirements of this standard. To enable direct quantification of total fugitive emissions based only on these methods, a subsequent revision of this standard will be needed.