Cena s DPH / bez DPH
Hlavní stránka>BS EN 15502-2-3:2023 Gas-fired central heating boilers Specific standard for hybrid units combining a gas-fired boiler and an electrical heat pump in a product
sklademVydáno: 2023-09-26
BS EN 15502-2-3:2023 Gas-fired central heating boilers Specific standard for hybrid units combining a gas-fired boiler and an electrical heat pump in a product

BS EN 15502-2-3:2023

Gas-fired central heating boilers Specific standard for hybrid units combining a gas-fired boiler and an electrical heat pump in a product

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8280 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
828.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2484.00 Kč
Anglicky Tisk
Skladem
8280 Kč
Označení normy:BS EN 15502-2-3:2023
Počet stran:46
Vydáno:2023-09-26
ISBN:978 0 539 17498 4
Status:Standard
Popis

BS EN 15502-2-3:2023


This standard BS EN 15502-2-3:2023 Gas-fired central heating boilers is classified in these ICS categories:
  • 27.060.30 Boilers and heat exchangers
  • 91.140.10 Central heating systems
This document specifies, the requirements and tests methods concerning, the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of hybrid units. The hybrid unit is composed by: — a gas boiler as heat generator which is able to supply the heat demand in all operating conditions; — an electrical heat pump air-to-water, as heat generator, which has not to fulfil the heat demand in all operating conditions; — a control unit (see definition 3.1.10). The hybrid unit may include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit. The gas boiler as part of the hybrid unit covered by this document is a gas-fired central heating boilers from the types C1 up to C9 and the types B2, B3 and B5, according to the classification in EN 1749:2020: a) that have a nominal heat input (on the basis of gross calorific value) not exceeding 400 kW; b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021; c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the water circuit does not exceed 6 bar; e) which shall be classified as a Gas-fired central heating boiler; f) which are intended to be installed either indoors or outdoors in a partially protected place; g) which are designed for either sealed water systems or for open water systems. This document provides requirements for boilers with known constructions. NOTE 1 For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed. NOTE 2 An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Regulation UE/426/2016, is given in Clause 11. This document does not cover all the requirements for: aa) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see EN 15502-1:2021, Annex AB); ab) appliances using flue dampers; ac) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71 and C81; ad) appliances incorporating flexible plastic flue liners; ae) appliances designed to become connected to a combined flue duct system. af) appliances of the types C(10),C(11), C(12) and C(13); ag) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW; ah) appliances intended to be connected to a flue having mechanical extraction; ai) surface temperatures of external parts particular to children and elderly people; aj) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas; ak) appliances equipped with an adaptive combustion control function (ACCF); al) boilers intended to be installed in areas accessible to elderly people and children. This document specifies minimum operating requirements which ensure that the products are fit for the use designated by the technical instructions when used for space heating and/or DHW production. This document is to be used in conjunction with: ba) the gas fired boiler, the generic part EN 15502 1:2021 and specific parts FprEN 15502-2-1:2022 and FprEN 15502-2-2:2022; bb) the electrical heat pump, EN 14511 4:2018, EN 378 1:2016+A1:2020, EN 378 2:2016 and FprEN 14825:2021; bc) electrical safety, EN 60335 1:2019, EN 60335 2 102:2016 and IEC 60335 2 40:2018; bd) for domestic hot water production, FprEN 13203 5:2022.