Cena s DPH / bez DPH
Hlavní stránka>BS EN 16146:2012+A1:2014 Sanitary tapware. Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2. General technical specification
sklademVydáno: 2014-12-31
BS EN 16146:2012+A1:2014 Sanitary tapware. Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2. General technical specification

BS EN 16146:2012+A1:2014

Sanitary tapware. Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2. General technical specification

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6240 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
624.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1872.00 Kč
Anglicky Tisk
Skladem
6240 Kč
Označení normy:BS EN 16146:2012+A1:2014
Počet stran:30
Vydáno:2014-12-31
ISBN:978 0 580 85652 5
Status:Standard
Popis

BS EN 16146:2012+A1:2014


This standard BS EN 16146:2012+A1:2014 Sanitary tapware. Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2. General technical specification is classified in these ICS categories:
  • 91.140.70 Sanitary installations

This European Standard applies to hoses for extractable outlets of any material intended for equipping sanitary tapware for sinks and basins. Such hoses will only be connected downstream of the obturator of the tapware. The tapware will comply with EN 200 , EN 817 , EN 1111 , EN 1286 or EN 1287 (see [1], [2], [3], [5] and [6]).

Hoses intended to connect sanitary tapware to the water supplies are not covered by this standard.

This European Standard specifies:

  • the dimensional, mechanical and hydraulic characteristics with which the hose for extractable outlets shall comply;

  • the procedures for testing these characteristics.

Details of pressures and temperatures are given in Table 1.

Table 1
Conditions of use/Classifications
Water supply system Operating range of hoses for extractable outlets Flow rates (Q) a
Limits Recommended
Type 1

see Figure 1

Dynamic Pressure

0,05 MPa ≤ P ≤ 0,5 MPa

(0,5 bar ≤ P ≤ 5 bar)
Dynamic Pressure

0,1 MPa to 0,3 MPa

(1,0 bar to 3,0 bar)
Class 1:

Q ≥ 0,25 l/s (15 l/min)

Class 2:

Q ≥ 0,15 l/s (9 l/min)

Type 2

see Figure 2

Dynamic Pressure

0,01 MPa to 0,2 MPa (0,1 bar to 2,0 bar)

Dynamic Pressure

0,02 MPa to 0,10 MPa (0,2 bar to 1,0 bar)

Class E:

0,06 l/s < Q < 0,18 l/s

(3,6 l/min < Q < 10,8 l/min.)
Class H:

0,18 l/s ≤ Q (10,8 l/min ≤ Q)

Temperature T ≤ 70°C T ≤ 60°C
a

See details in Table 3.

[Image removed.]

[Image removed.]