Cena s DPH / bez DPH
Hlavní stránka>BS EN 16206:2012 Animal feeding stuffs. Determination of arsenic by hydride generation atomic absorption spectrometry (HGAAS) after microwave pressure digestion (digestion with 65 % nitric acid and 30 % hydrogen peroxide)
Sponsored link
sklademVydáno: 2012-02-29
BS EN 16206:2012 Animal feeding stuffs. Determination of arsenic by hydride generation atomic absorption spectrometry (HGAAS) after microwave pressure digestion (digestion with 65 % nitric acid and 30 % hydrogen peroxide)

BS EN 16206:2012

Animal feeding stuffs. Determination of arsenic by hydride generation atomic absorption spectrometry (HGAAS) after microwave pressure digestion (digestion with 65 % nitric acid and 30 % hydrogen peroxide)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4800 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
480.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1440.00 Kč
Anglicky Tisk
Skladem
4800 Kč
Označení normy:BS EN 16206:2012
Počet stran:20
Vydáno:2012-02-29
ISBN:978 0 580 66996 5
Status:Standard
Popis

BS EN 16206:2012


This standard BS EN 16206:2012 Animal feeding stuffs. Determination of arsenic by hydride generation atomic absorption spectrometry (HGAAS) after microwave pressure digestion (digestion with 65 % nitric acid and 30 % hydrogen peroxide) is classified in these ICS categories:
  • 65.120 Animal feeding stuffs

This European Standard specifies a method for the determination of total arsenic in animal feeding stuffs by hydride generation atomic absorption spectrometry (HGAAS) after microwave pressure digestion. The limit of quantification is 0,5 μg/l of the test solution. Using a test portion of 0,5 g, a volume of the test solution of 25 ml and an aliquot of 5 ml for pre-reduction the limit of quantification is 0,125 mg/kg in the feed material.

NOTE For feed materials containing organic arsenic species from compounds of marine origin (i.e. arsenobetaine and tetramethylarsine oxide) a higher digestion temperature of the microwave system up to 300 °C may be necessary in order to enable the hydridisation of these arsenic compounds and in order to determine all different kinds of arsenic species in the corresponding feeding stuffs. Alternatively, the digestion procedure of Annex C can be used if the microwave system does not reach higher temperatures up to 300 °C to ensure complete mineralization for HGAAS determination.