Cena s DPH / bez DPH
Hlavní stránka>BS EN 16329:2022 Diesel and domestic heating fuels. Determination of cold filter plugging point. Linear cooling bath method
Sponsored link
sklademVydáno: 2022-11-10
BS EN 16329:2022 Diesel and domestic heating fuels. Determination of cold filter plugging point. Linear cooling bath method

BS EN 16329:2022

Diesel and domestic heating fuels. Determination of cold filter plugging point. Linear cooling bath method

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4650 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
465.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1395.00 Kč
Anglicky Tisk
Skladem
4650 Kč
Označení normy:BS EN 16329:2022
Počet stran:22
Vydáno:2022-11-10
ISBN:978 0 539 18695 6
Status:Standard
Popis

BS EN 16329:2022


This standard BS EN 16329:2022 Diesel and domestic heating fuels. Determination of cold filter plugging point. Linear cooling bath method is classified in these ICS categories:
  • 75.160.20 Liquid fuels
This document specifies an automated method for the determination of the cold filter plugging point (CFPP) of diesel and domestic heating fuels using linear cooling. This document is applicable to fatty-acid methyl esters (FAME) and to distillate fuels as well as paraffinic diesel fuels, including those containing FAME, flow-improvers or other additives, intended for use in diesel engines and domestic heating installations. The results obtained from the method specified in this document are suitable for estimating the lowest temperature at which a fuel will give trouble-free flow in the fuel system. NOTE In the case of diesel fuels, the results are usually close to the temperature of failure in service except when the fuel system contains, for example, a paper filter installed in a location exposed to the weather or if the filter plugging temperature is more than 12 °C below the cloud point of the fuel. Domestic heating installations are usually less critical and often operate at a satisfactory level at temperatures somewhat lower than those indicated by the test results. WARNING - The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.