Cena s DPH / bez DPH
Hlavní stránka>BS EN 1793-6:2018+A1:2021 Road traffic noise reducing devices. Test method for determining the acoustic performance Intrinsic characteristics. In situ values of airborne sound insulation under direct sound field conditions
sklademVydáno: 2021-03-19
BS EN 1793-6:2018+A1:2021 Road traffic noise reducing devices. Test method for determining the acoustic performance Intrinsic characteristics. In situ values of airborne sound insulation under direct sound field conditions

BS EN 1793-6:2018+A1:2021

Road traffic noise reducing devices. Test method for determining the acoustic performance Intrinsic characteristics. In situ values of airborne sound insulation under direct sound field conditions

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8700 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
870.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2610.00 Kč
Anglicky Tisk
Skladem
8700 Kč
Označení normy:BS EN 1793-6:2018+A1:2021
Počet stran:54
Vydáno:2021-03-19
ISBN:978 0 539 05195 7
Status:Standard
Popis

BS EN 1793-6:2018+A1:2021


This standard BS EN 1793-6:2018+A1:2021 Road traffic noise reducing devices. Test method for determining the acoustic performance is classified in these ICS categories:
  • 93.080.30 Road equipment and installations
  • 17.140.30 Noise emitted by means of transport

This document describes a test method for measuring a quantity representative of the intrinsic characteristics of airborne sound insulation for traffic noise reducing devices: the sound insulation index.

The test method is intended for the following applications:

  • determination of the intrinsic characteristics of airborne sound insulation of noise reducing devices to be installed along roads, to be measured either in situ or in laboratory conditions;

  • determination of the in situ intrinsic characteristics of airborne sound insulation of noise reducing devices in actual use;

  • comparison of design specifications with actual performance data after the completion of the construction work;

  • verification of the long term performance of noise reducing devices (with a repeated application of the method);

  • interactive design process of new products, including the formulation of installation manuals.

The test method is not intended for the determination of the intrinsic characteristics of airborne sound insulation of noise reducing devices to be installed in reverberant conditions, e.g. inside tunnels or deep trenches or under covers.

Results are expressed as a function of frequency in one-third octave bands, where possible, between 100 Hz and 5 kHz. If it is not possible to get valid measurement results over the whole frequency range indicated, the results will be given in a restricted frequency range and the reasons for the restriction(s) will be clearly reported.