Cena s DPH / bez DPH
Hlavní stránka>BS EN 1996-1-2:2005 Eurocode 6. Design of masonry structures General rules. Structural fire design
Sponsored link
sklademVydáno: 2011-07-31
BS EN 1996-1-2:2005 Eurocode 6. Design of masonry structures General rules. Structural fire design

BS EN 1996-1-2:2005

Eurocode 6. Design of masonry structures General rules. Structural fire design

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9734 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
973.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2920.20 Kč
Anglicky Tisk
Skladem
9734 Kč
Označení normy:BS EN 1996-1-2:2005
Počet stran:86
Vydáno:2011-07-31
ISBN:978 0 580 73699 5
Status:Standard
Popis

BS EN 1996-1-2:2005


This standard BS EN 1996-1-2:2005 Eurocode 6. Design of masonry structures is classified in these ICS categories:
  • 91.080.30 Masonry
  • 13.220.50 Fire-resistance of building materials and elements
  • 91.010.30 Technical aspects

(1)P This Part 1-2 of EN 1996 deals with the design of masonry structures for the accidental situation of fire exposure, and is intended to be used in conjunction with EN 1996-1-1, EN 1996-2, 1996-3 and EN 1991-1-2. This part 1-2 only identifies differences from, or supplements to, normal temperature design.

(2)P This Part 1-2 deals only with passive methods of fire protection. Active methods are not covered.

(3)P This Part 1-2 applies to masonry structures which, for reasons of general fire safety, are required to fulfil certain functions when exposed to fire, in terms of:

  • avoiding premature collapse of the structure (load bearing function)
  • limiting fire spread (flames, hot gases, excessive heat) beyond designated areas (separating function)

(4)P This Part 1-2 gives principles and application rules for designing structures for specified requirements in respect of the aforementioned functions and levels of performance.

(5)P This Part 1-2 applies to structures, or parts of structures, that are within the scope of EN 1996-1-1, EN 1996-2 and EN 1996-3 and are designed accordingly.

(6)P This Part 1-2 does not cover masonry built with Natural Stone units to EN771-6

(7)P This Part 1-2 deals with the following:

  • non-loadbearing internal walls.
  • non-loadbearing external walls.
  • loadbearing internal walls with separating or non-separating functions.
  • loadbearing external walls with separating or non-separating functions.