Cena s DPH / bez DPH
Hlavní stránka>BS EN 1998-2:2005+A2:2011 Eurocode 8. Design of structures for earthquake resistance Bridges
sklademVydáno: 2012-02-29
BS EN 1998-2:2005+A2:2011 Eurocode 8. Design of structures for earthquake resistance Bridges

BS EN 1998-2:2005+A2:2011

Eurocode 8. Design of structures for earthquake resistance Bridges

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9420 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
942.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2826.00 Kč
Anglicky Tisk
Skladem
9420 Kč
Označení normy:BS EN 1998-2:2005+A2:2011
Počet stran:154
Vydáno:2012-02-29
ISBN:978 0 580 78322 7
Status:Standard
Popis

BS EN 1998-2:2005+A2:2011


This standard BS EN 1998-2:2005+A2:2011 Eurocode 8. Design of structures for earthquake resistance is classified in these ICS categories:
  • 91.120.25 Seismic and vibration protection
  • 93.040 Bridge construction

1.1.1 Scope of EN 1998-2

  1. The scope of Eurocode 8 is defined in EN 1998-1:2004, 1.1.1 and the scope of this Standard is defined in 1.1.1. Additional parts of Eurocode 8 are indicated in EN 1998-1:2004, 1.1.3.

  2. Within the framework of the scope set forth in EN 1998-1:2004, this part of the Standard contains the particular Performance Requirements, Compliance Criteria and Application Rules applicable to the design of earthquake resistant bridges.

  3. This Part primarily covers the seismic design of bridges in which the horizontal seismic actions are mainly resisted through bending of the piers or at the abutments; i.e. of bridges composed of vertical or nearly vertical pier systems supporting the traffic deck superstructure. It is also applicable to the seismic design of cable-stayed and arched bridges, although its provisions should not be considered as fully covering these cases.

  4. Suspension bridges, timber and masonry bridges, moveable bridges and floating bridges are not included in the scope of this Part.

  5. This Part contains only those provisions that, in addition to other relevant Eurocodes or relevant Parts of EN 1998, should be observed for the design of bridges in seismic regions. In cases of low seismicity, simplified design criteria may be established (see 2.3.7(1)).

  6. The following topics are dealt with in the text of this Part:

    • Basic requirements and Compliance Criteria,

    • Seismic Action,

    • Analysis,

    • Strength Verification,

    • Detailing.

    This Part also includes a special section on seismic isolation with provisions covering the application of this method of seismic protection to bridges.

  7. Annex G contains rules for the calculation of capacity design effects.

  8. Annex J contains rules regarding the variation of design properties of seismic isolator units and how such variation may be taken into account in design.

NOTE 1 Informative Annex A provides information for the probabilities of the reference seismic event and recommendations for the selection of the design seismic action during the construction phase.

NOTE 2 Informative Annex B provides information on the relationship between the displacement ductility and the curvature ductility of plastic hinges in concrete piers.

NOTE 3 Informative Annex C provides information for the estimation of the effective stiffness of reinforced concrete ductile members.

NOTE 4 Informative Annex D provides information for modelling and analysis for the spatial variability of earthquake ground motion.

NOTE 5 Informative Annex E gives information on probable material properties and plastic hinge deformation capacities for non-linear analyses.

NOTE 6 Informative Annex F gives information and guidance for the added mass of entrained water in immersed piers.

NOTE 7 Informative Annex H provides guidance and information for static non-linear analysis (pushover).

NOTE 8 Informative Annex JJ provides information on λ-factors for common isolator types.

NOTE 9 Informative Annex K contains tests requirements for validation of design properties of seismic isolator units.