sklademVydáno: 2017-01-31
BS EN 50121-2:2017 Railway applications. Electromagnetic compatibility Emission of the whole railway system to the outside world

BS EN 50121-2:2017

Railway applications. Electromagnetic compatibility Emission of the whole railway system to the outside world

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6820 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
682.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2046.00 Kč
Anglicky Tisk
Skladem
6820 Kč
Označení normy:BS EN 50121-2:2017
Počet stran:30
Vydáno:2017-01-31
ISBN:978 0 580 94100 9
Status:Standard
Popis

BS EN 50121-2:2017


This standard BS EN 50121-2:2017 Railway applications. Electromagnetic compatibility is classified in these ICS categories:
  • 45.020 Railway engineering in general
  • 29.020 Electrical engineering in general
  • 33.100.01 Electromagnetic compatibility in general

This European Standard is intended to define the electromagnetic environment of the whole railway system including urban mass transit and light rail system. It describes the measurement method to verify the emissions, and gives the cartography values of the fields most frequently encountered.

This European Standard specifies the emission limits of the whole railway system to the outside world.

The emission parameters refer to the particular measuring points defined in Clause 5. These emissions should be assumed to exist at all points in the vertical planes which are 10 m from the centre lines of the outer electrified railway tracks, or 10 m from the fence of the substations.

Also, the zones above and below the railway system may be affected by electromagnetic emissions and particular cases need to be considered individually.

These specific provisions need to be used in conjunction with the general provisions in EN 50121‑1 .

For existing railway lines, it is assumed that compliance with the emission requirements of EN 50121‑3‑1 , EN 50121‑3‑2 , EN 50121‑4 and EN 50121‑5 will ensure the compliance with the emission values given in this part.

For newly built railway systems it is best practice to provide compliance to the emission limits given in this part of the standard (as defined in the EMC plan according to EN 50121‑1 ).