Hlavní stránka>BS EN 50174-3:2013+A1:2017 Information technology. Cabling installation Part 3: Installation planning and practices outside buildings
Sponsored link
sklademVydáno: 2018-03-19
BS EN 50174-3:2013+A1:2017 Information technology. Cabling installation Part 3: Installation planning and practices outside buildings

BS EN 50174-3:2013+A1:2017

Information technology. Cabling installation Part 3: Installation planning and practices outside buildings

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
10230 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
1023.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
3069.00 Kč
Anglicky Tisk
Skladem
10230 Kč
Označení normy:BS EN 50174-3:2013+A1:2017
Počet stran:118
Vydáno:2018-03-19
ISBN:978 0 580 95893 9
Status:Standard
Popis

BS EN 50174-3:2013+A1:2017


This standard BS EN 50174-3:2013+A1:2017 Information technology. Cabling installation is classified in these ICS categories:
  • 35.110 Networking
  • 91.140.50 Electricity supply systems
  • 33.040.50 Lines, connections and circuits
This European Standard specifies requirements and provides recommendations for the following aspects of information technology cabling: a) planning; b) installation practice. This European Standard is applicable to all types of information technology cabling outside buildings including generic cabling systems designed in accordance with EN 50173 series. The requirements and recommendations of this European Standard may be applied to cabling that is defined as part of the building. The requirements and recommendations of Clauses 4, 5 and 6 of this European Standard are subject to any site-specific requirements and recommendations of Clause 7. The planning of the pathway systems, spaces and structures within the core and access network cabling as described in Figure 2 that are owned by access providers is excluded except for requirements and recommendations that provide basic safety, function and environmental objectives for mechanical, ingress and climatic characteristics (i.e. excluding pathway dimensions, distribution of spaces and similar constraints based on specific transmission methods). The installation practices applicable to all cabling installation methods are included by the provision of the necessary planning requirements and recommendations associated with each one with the exception of information technology cabling installed: – around or within aerial power supply or associated earth conductors; – on infrastructures carrying power supplies in excess of AC/DC 25 kV. This European Standard: 1) details the considerations for satisfactory installation and operation of information technology cabling; 2) excludes specific requirements applicable to other cabling systems (e.g. power supply cabling); however, it takes account of the effects other cabling systems may have on the installation of information technology cabling (and vice versa) and gives general advice; 3) excludes those aspects of installation associated with the transmission of signals in free space between transmitters, receivers or their associated antenna systems (e.g. wireless, radio, microwave or satellite). This European Standard is applicable to certain hazardous environments. It does not exclude additional requirements which are applicable in particular circumstances, defined by e.g. electricity supply and electrified railways. The requirements within this European Standard do not cover any additional requirements for the information technology cables installed in hazardous or stressful environments e.g. electricity supply and electric railway locations (see Clause 7).