Cena s DPH / bez DPH
Hlavní stránka>BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables
sklademVydáno: 2008-08-29
BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables

BS EN 50264-3-1:2008

Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6240 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
624.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1872.00 Kč
Anglicky Tisk
Skladem
6240 Kč
Označení normy:BS EN 50264-3-1:2008
Počet stran:28
Vydáno:2008-08-29
ISBN:978 0 580 64073 5
Status:Standard
Popis

BS EN 50264-3-1:2008


This standard BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance is classified in these ICS categories:
  • 13.220.20 Fire protection
  • 45.060.01 Railway rolling stock in general
  • 29.060.20 Cables

EN 50264-3-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings:

  • 0,6/1 kV unscreened, unsheathed (1 mm2 to 400 mm2);

  • 1,8/3 kV unscreened, unsheathed (1,5 mm2 to 400 mm2);

  • 1,8/3 kV unscreened, sheathed (1,5 mm2 to 400 mm2);

  • 3,6/6 kV unscreened, sheathed (2,5 mm2 to 400 mm2).

All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is ncountered. The requirements provide for a continuous conductor temperature not exceeding 90° C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s.

Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases.

EN 50264-3-1 should be read in conjunction with Part 1 “General requirements”.