Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN 50290-2-27:2021 Communication cables Common design rules and construction. Halogen free polyolefin based sheathing compounds for cables having improved flame and fire properties (HFFR)
Sponsored link
sklademVydáno: 2021-05-12
BS EN 50290-2-27:2021 Communication cables Common design rules and construction. Halogen free polyolefin based sheathing compounds for cables having improved flame and fire properties (HFFR)

BS EN 50290-2-27:2021

Communication cables Common design rules and construction. Halogen free polyolefin based sheathing compounds for cables having improved flame and fire properties (HFFR)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4154 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
415.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1246.20 Kč
Anglicky Tisk
Skladem
4154 Kč
Označení normy:BS EN 50290-2-27:2021
Počet stran:12
Vydáno:2021-05-12
ISBN:978 0 539 14719 3
Status:Standard
Popis

BS EN 50290-2-27:2021


This standard BS EN 50290-2-27:2021 Communication cables is classified in these ICS categories:
  • 33.120.10 Coaxial cables. Waveguides
  • 29.035.20 Plastics and rubber insulating materials

This document gives specific requirements for halogen free polyolefin based sheathing compounds used for halogen free communication cables with improved characteristics in the case of fire.

Compounds, described by this document, are commonly also named HFFR or HFFR-LS (halogen free, flame/fire retardant, low smoke), see also EN 50290-2-20.

It is expected to be read in conjunction with EN 50290-2-20, the product standards EN 50288 series, EN 60794 series and other applicable product standards.

Improved characteristics in the case of fire are demonstrated by specific fire tests on cables for flame/fire retardant applications (e.g. single or bunched cable fire test). Additional tests to prove the characteristics in case of fire, e.g. such as smoke emission test, might also be part of the dedicated product standard or specification.

This document describes the compound types as given in Table 1.

Table 1 Sheathing compounds

Compound grades

Max. operating temperature

°C

Comment
Type 1 +70 thermoplastic standard
Type 2 +90 thermoplastic, higher temperature
Type 3 +90 crosslinked, higher temperature