Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN 50306-1:2020 Railway applications. Railway rolling stock cables having special fire performance. Thin wall General requirements
Sponsored link
sklademVydáno: 2020-04-02
BS EN 50306-1:2020 Railway applications. Railway rolling stock cables having special fire performance. Thin wall General requirements

BS EN 50306-1:2020

Railway applications. Railway rolling stock cables having special fire performance. Thin wall General requirements

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4898 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
489.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1469.40 Kč
Anglicky Tisk
Skladem
4898 Kč
Označení normy:BS EN 50306-1:2020
Počet stran:20
Vydáno:2020-04-02
ISBN:978 0 580 93926 6
Status:Standard
Popis

BS EN 50306-1:2020


This standard BS EN 50306-1:2020 Railway applications. Railway rolling stock cables having special fire performance. Thin wall is classified in these ICS categories:
  • 13.220.40 Ignitability and burning behaviour of materials and products
  • 29.060.20 Cables
  • 45.060.01 Railway rolling stock in general

EN 50306-1 specifies the general requirements applicable to the cables given in EN 50306-2, EN 50306-3 and EN 50306-4. It includes the detailed requirements for S2 sheathing materials and other components called up in the separate parts.

NOTE Detailed requirements for insulation systems are given in EN 50306-2.

In particular, EN 50306-1 specifies those requirements relating to fire safety which enable the cables to satisfy Hazard Level 3 of EN 45545-1 and EN 45545-2.

These cables are rated for occasional thermal stresses which causes ageing equivalent to continuous operational life at a temperature of 105 °C or 90 °C. For standard cables, this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 125 °C or 110 °C /20 000 h temperature index. If the customer were to require lifetime predictions, this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s.

EN 50306-1 is expected to be used in conjunction with one or more of the other parts of EN 50306.