BS EN 50399:2022 Common test methods for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results

BS EN 50399:2022

Common test methods for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9734 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
973.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2920.20 Kč
Anglicky Tisk
Skladem
9734 Kč
Označení normy:BS EN 50399:2022
Počet stran:88
Vydáno:2022-10-31
ISBN:978 0 539 12234 3
Status:Standard
Popis

BS EN 50399:2022


This standard BS EN 50399:2022 Common test methods for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results is classified in these ICS categories:
  • 29.060.20 Cables
  • 13.220.40 Ignitability and burning behaviour of materials and products
This document specifies the apparatus and methods of test for the assessment of vertical flame spread, heat release, smoke production and occurrence of flaming droplets/particles of vertically mounted electric cables under defined conditions. NOTE For the purpose of this document, the term “electric cable” covers all power, control and communication cables, including optical fibre cables and hybrid cables used for the conveyance of energy and/or signals. This document details the apparatus for the fire propagation testing and the arrangement and calibration of the instrumentation to be installed to measure the heat release and the smoke production during the test. The combustion gases are collected in a hood above the test chamber and conveyed through an exhaust system, which allows the measurement of heat release rate and smoke production. Test procedures to be used for type approval testing for classification of cables in classes [2, 7] B1ca, B2ca, Cca and Dca are given. Cable installation on the test ladder and the volume of air passing through the chamber are in accordance with the Commission Decision 2006/751/EC [6], which is reflected in the requirements of this document.