Cena s DPH / bez DPH
Hlavní stránka>BS EN 50518:2019+A1:2023 Monitoring and Alarm Receiving Centre
Sponsored link
sklademVydáno: 2023-05-31
BS EN 50518:2019+A1:2023 Monitoring and Alarm Receiving Centre

BS EN 50518:2019+A1:2023

Monitoring and Alarm Receiving Centre

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8556 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
855.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2566.80 Kč
Anglicky Tisk
Skladem
8556 Kč
Označení normy:BS EN 50518:2019+A1:2023
Počet stran:50
Vydáno:2023-05-31
ISBN:978 0 539 21314 0
Status:Standard
Popis

BS EN 50518:2019+A1:2023


This standard BS EN 50518:2019+A1:2023 Monitoring and Alarm Receiving Centre is classified in these ICS categories:
  • 13.320 Alarm and warning systems
This document specifies the minimum requirements for monitoring, receiving and processing of alarm messages generated by alarm systems taking place as a part of the total fire, safety and security solution. For the purpose of this document, the term “alarm” is used in the broad sense to include fault, status and other messages received from one or more of a range of safety and security alarm systems such as but not limited to fire detection and fire alarm systems, fixed firefighting systems, intrusion and hold-up alarm systems, access control systems, video surveillance systems, social alarms systems and combinations of such systems. This document gives requirements for two categories of ARC, category I and category II. A category I ARC will be designed, constructed and operated to a higher standard with respect to construction, security and integrity than a category II ARC. The categorization is determined according to the type(s) of alarm messages handled. Category I: ARCs handling messages from security applications: - I&HAS’s; - access control systems; - VSS in security applications that require an emergency response (for example loss prevention); - people monitoring, lone workers and object tracking systems for security applications; - alarm messages handled by category II ARCs; - combinations of the above systems. Category II: ARC’s handling messages from non-security applications: - fire alarm systems; - fixed firefighting systems; - social alarm systems; - audio/video door entry systems; - VSS in non-security applications (for example traffic flow); - people monitoring, lone workers and object tracking systems for non-security applications; - lifts emergency systems; - combinations of the above systems. The requirements apply to ARC’s (whether established in single or multiple sites) monitoring and processing alarms generated by systems installed at other locations and also to ARC’s monitoring solely alarms from systems within their own site. The document includes functional and specific requirements supporting the services of an ARC. The document does NOT apply to: - alarm systems used for non-civil purposes; - alarm systems for medical or health applications.