Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN 55011:2016+A2:2021 Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement
Sponsored link
sklademVydáno: 2021-04-14
BS EN 55011:2016+A2:2021 Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement

BS EN 55011:2016+A2:2021

Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
10230 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
1023.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
3069.00 Kč
Anglicky Tisk
Skladem
10230 Kč
Označení normy:BS EN 55011:2016+A2:2021
Počet stran:110
Vydáno:2021-04-14
ISBN:978 0 580 97670 4
Status:Standard
Popis

BS EN 55011:2016+A2:2021


This standard BS EN 55011:2016+A2:2021 Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement is classified in these ICS categories:
  • 33.100.10 Emission

This International Standard applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate and/or use locally radio‑frequency energy.

This standard covers emission requirements related to radio‑frequency (RF) disturbances in the frequency range of 9 kHz to 400 GHz. Measurements need only be performed in frequency ranges where limits are specified in Clause 6.

For ISM RF applications in the meaning of the definition found in the ITU Radio Regulations (see Definition 3.13), this standard covers emission requirements related to radio‑frequency disturbances in the frequency range of 9 kHz to 18 GHz.

NOTE Emission requirements for induction cooking appliances are specified in CISPR 14‑1 [1]1.

Requirements for ISM RF lighting equipment and UV irradiators operating at frequencies within the ISM frequency bands defined by the ITU Radio Regulations are contained in this standard.

Equipment covered by other CISPR product and product family emission standards are excluded from the scope of this standard.