Cena s DPH / bez DPH
Hlavní stránka>BS EN 60079-10-2:2015 Explosive atmospheres Classification of areas. Explosive dust atmospheres
Sponsored link
sklademVydáno: 2015-03-31
BS EN 60079-10-2:2015 Explosive atmospheres Classification of areas. Explosive dust atmospheres

BS EN 60079-10-2:2015

Explosive atmospheres Classification of areas. Explosive dust atmospheres

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6448 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
644.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1934.40 Kč
Anglicky Tisk
Skladem
6448 Kč
Označení normy:BS EN 60079-10-2:2015
Počet stran:30
Vydáno:2015-03-31
ISBN:978 0 580 80696 4
Status:Standard
Popis

BS EN 60079-10-2:2015


This standard BS EN 60079-10-2:2015 Explosive atmospheres is classified in these ICS categories:
  • 13.230 Explosion protection
  • 29.260.20 Electrical apparatus for explosive atmospheres

This part of IEC 60079 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas.

In this standard, explosive dust atmospheres and combustible dust layers are treated separately. In Clause 4, area classification for explosive dusts clouds is described, with dust layers acting as one of the possible sources of release. In Clause 7 other general considerations for dust layers are described.

The examples in this standard are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers.

The principles of this standard can also be followed when combustible fibres or flyings might cause a hazard.

This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions (see Note 1).

NOTE 1

Atmospheric conditions include variations in pressure and temperature above and below reference levels of 101,3 kPa (1 013 mbar) and 20 °C (293 K), provided that the variations have a negligible effect on the explosive properties of the combustible materials.

It does not apply to

  • underground mining areas,

  • dusts of explosives that do not require atmospheric oxygen for combustion such as pyrophoric substances, propellants, pyrotechnics, munitions, peroxides, oxidizers, water-reactive elements or compounds, or other similar materials.

  • catastrophic failures which are beyond the concept of abnormality dealt with in this standard,

  • any risk arising from an emission of toxic gas from the dust.

This standard does not apply to where a hazard might arise due to the presence of flammable gas or vapour, but the principles may be used in the assessment of a hybrid mixture (see also IEC 60079‑10‑1 ).

NOTE 2

Additional guidance on hybrid mixtures is provided in Annex C.