Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN 60079-29-4:2010 Explosive atmospheres Gas detectors. Performance requirements of open path detectors for flammable gases
Sponsored link
sklademVydáno: 2011-07-31
BS EN 60079-29-4:2010 Explosive atmospheres Gas detectors. Performance requirements of open path detectors for flammable gases

BS EN 60079-29-4:2010

Explosive atmospheres Gas detectors. Performance requirements of open path detectors for flammable gases

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7998 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
799.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2399.40 Kč
Anglicky Tisk
Skladem
7998 Kč
Označení normy:BS EN 60079-29-4:2010
Počet stran:40
Vydáno:2011-07-31
ISBN:978 0 580 72991 1
Status:Standard
Popis

BS EN 60079-29-4:2010


This standard BS EN 60079-29-4:2010 Explosive atmospheres is classified in these ICS categories:
  • 29.260.20 Electrical apparatus for explosive atmospheres
  • 13.320 Alarm and warning systems

This part of EN 60079-29 specifies performance requirements of equipment for the detection and measuring of flammable gases or vapours in ambient air by measuring the spectral absorption by the gases or vapours over extended optical paths, ranging typically from one metre to a few kilometres.

Such equipment measures the integral concentration of the absorbing gas over the optical path in units such as LFL metre for flammable gases.

NOTE 1 Actual values of concentration can be deduced only where it can be established that the concentration is uniform over the optical path, for example in very short optical paths (< 100 mm). In such cases, the equipment is within the scope of EN 60079-29-1.

NOTE 2 This standard is based upon present absorption techniques using infrared radiation. Other techniques and applications may require additional test considerations (e.g. pressure test).

Equipment falling within the scope of this standard is classified by the following types:

Type 1: an optical transmitter and receiver, located at either end of a path through the atmosphere to be monitored.

Type 2: an optical transceiver (i.e. combined transmitter and receiver) and a suitable reflector, which may be a topographic feature or a retroreflector, located at either end of a path through the atmosphere to be monitored.

This standard is also applicable when an equipment manufacturer makes any claims regarding any special features of construction or superior performance that exceed the minimum requirements of this standard. All such claims shall be verified and the test procedures should be extended or supplemented, where necessary, to verify the claimed performance. The additional tests shall be agreed between the manufacturer and the test laboratory and identified and described in the test report.

This standard does not apply to any of following:

  1. equipment intended to provide range resolution of gas concentration (e.g. Light direction and ranging (LIDAR));

  2. equipment consisting of a passive optical receiver without a dedicated optical source;

  3. equipment intended to measure the local volumetric concentration of gas (point sensors);

  4. equipment intended for the detection of dusts or mists in air;

  5. equipment for cross stack monitoring;

  6. equipment intended for the detection of explosives; and

  7. equipment intended only for the identification of individual gas or vapour components, (e.g. Fourier transform infrared spectroscopy (FTIR)).

This standard is applicable to equipment which is intended for use in hazardous or nonhazardous areas, or both. Equipment for use in hazardous areas is also required to have explosion protection (see 4.1.1).

This standard applies to portable, transportable and fixed equipment intended for commercial and industrial applications.