BS EN 60079-35-1:2011
Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusement machines and personal service machines
Označení normy: | BS EN 60079-35-1:2011 |
Počet stran: | 26 |
Vydáno: | 2012-03-31 |
ISBN: | 978 0 580 76787 6 |
Status: | Standard |
BS EN 60079-35-1:2011
This standard BS EN 60079-35-1:2011 Household and similar electrical appliances - Safety is classified in these ICS categories:
- 97.180 Miscellaneous domestic and commercial equipment
- 97.200.40 Playgrounds
- 29.260.20 Electrical apparatus for explosive atmospheres
This part of IEC 60079-35 specifies requirements for the construction, testing and marking of caplights, including caplights with a point of connection for other equipment, for use in mines susceptible to firedamp (Group I – electrical equipment for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition.
The requirements for performance are in IEC 60079-35-2.1
This standard supplements and modifies the general requirements of IEC 60079-0 except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirements of this standard take precedence.
Compliance with this standard will provide an EPL of Mb (see 4.1 of this standard). If an EPL of Ma is required, the caplight will need to conform to the requirements of 4.2 of this standard, which in turn refers to IEC 60079-11.
It is expected that from time to time, caplights conforming to this standard (EPL Mb) will operate in atmospheres where the firedamp exceeds statutory levels that require the withdrawal of people from the high firedamp atmosphere to a non-hazardous area.
In designing equipment for operation in conditions other than those given above, this standard may be used as guidance; however, additional testing may be required.
Where a caplight is assessed as intrinsically safe equipment, Ex ia, conforming to IEC 60079-11 only the clauses/subclauses listed in 4.2 require application.
Table 1 – Application or exclusion of specific clauses of IEC 60079-0
Clause of IEC 60079-0 | IEC 60079-0 clause application | ||
---|---|---|---|
Ed. 5.0a (2007) | Ed. 6.0a (2011) | Clause/subclause title (normative) | |
1 | 1 | Scope | Applies |
2 | 2 | Normative references | Applies |
3 | 3 | Terms and definitions | Applies |
4 | 4 | Equipment grouping | Applies |
5 | 5 | Temperatures | Applies |
6.1 | 6.1 | Requirements for all equipment – General | Applies |
6.2 | 6.2 | Requirements for all equipment – Mechanical strength of equipment | Applies |
6.3 | 6.3 | Requirements for all equipment – Opening times | Excluded |
6.4 | 6.4 | Requirements for all equipment – Circulating currents | Excluded |
6.5 | 6.5 | Requirements for all equipment – Gasket retention | Applies |
6.6 | 6.6 | Requirements for all equipment – Electromagnetic and ultrasonic energy radiating equipment | Applies |
7 | 7 | Non-metallic enclosures and non-metallic parts of enclosures | Applies |
8 | 8 | Metallic enclosures and metallic parts of enclosures | Applies |
9 | 9 | Fasteners | Applies |
10 | 10 | Interlocking devices | Applies |
11 | 11 | Bushings | Excluded |
12 | 12 | Materials used for cementing | Applies |
13 | 13 | Ex components | Applies |
14 | 14 | Connection facilities and terminal compartments | Applies |
15 | 15 | Connection facilities for earthing or bonding conductors | Excluded |
16 | 16 | Entries into enclosures | Applies |
17 | 17 | Supplementary requirements for rotating electrical machines | Excluded |
18 | 18 | Supplementary requirements for switchgear | Excluded |
19 | 19 | Supplementary requirements for fuses | Excluded |
20 | 20 | Supplementary requirements for plugs and socket outlets and connectors | Applies |
21 | 21 | Supplementary requirements for luminaires | Excluded |
22 | 22 | Supplementary requirements for caplights and handlights | Applies |
23 | 23 | Equipment incorporating cells and batteries | Modified |
24 | 24 | Documentation | Applies |
25 | 25 | Compliance of prototype or sample with documents | Applies |
26.1 | 26.1 | Type tests – General | Applies |
26.2 | 26.2 | Type tests – Test configuration | Applies |
26.3 | 26.3 | Type tests – Tests in explosive test mixtures | Applies |
26.4 | 26.4 | Type tests – Tests of enclosures | Modified |
26.5.1 | 26.5.1 | Thermal tests – Temperature measurement | Applies |
26.5.2 | 26.5.2 | Thermal tests – Thermal shock test | Applies |
26.5.3 | 26.5.3 | Thermal tests – Small component ignition test | Applies |
26.6 | 26.6 | Torque tests for bushings | Excluded |
26.7 | 26.7 | Non-metallic enclosures or non-metallic parts of enclosures | Applies |
26.8 | 26.8 | Thermal endurance to heat | Applies |
26.9 | 26.9 | Thermal endurance to cold | Applies |
26.10 | 26.10 | Resistance to light | Excluded |
26.11 | 26.11 | Resistance to chemical agents for Group I electrical equipment | Applies |
26.12 | 26.12 | Earth continuity | Excluded |
26.13 | 26.13 | Surface resistance of parts of enclosures of non-metallic materials | Applies |
26.14 | NR | Charging tests | Applies |
26.15 | 26.14 | Measurement of capacitance | Applies |
NR | 26.15 | Verification of ratings of ventilating fans | Excluded |
NR | 26.16 | Alternative qualification of elastomeric sealing O-rings | Applies |
27 | 27 | Routine tests | Applies |
28 | 28 | Manufacturer's responsibility | Applies |
29 | 29 | Marking | Modified |
30 | 30 | Instructions | Applies |
Applies – This requirement of IEC 60079-0 is applied without change.
Excluded – This requirement of IEC 60079-0 does not apply.
Modified – This requirement of IEC 60079-0 is modified as detailed in this standard.
NR – No requirements.
a The clause number in this table is shown for information only. The applicable requirements of IEC 60079-0 are identified by the clause title which is normative. This table was written against the specific requirements of the sixth edition of IEC 60079-0:2011. The clause numbers for the previous edition are shown for information only. This is to enable the General requirements of the fifth edition of IEC 60079-0:2007 to be used where necessary with this part of IEC 60079. Where there were no requirements (indicated by NR) or there is a conflict between requirements, the later edition requirements take precedence.