Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN 60534-2-1:2011 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC. Equipment for testing, measuring or monitoring of protective measures Power metering and monitoring devices (PMD)
Sponsored link
sklademVydáno: 2015-06-30
BS EN 60534-2-1:2011 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC. Equipment for testing, measuring or monitoring of protective measures Power metering and monitoring devices (PMD)

BS EN 60534-2-1:2011

Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC. Equipment for testing, measuring or monitoring of protective measures Power metering and monitoring devices (PMD)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9486 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
948.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2845.80 Kč
Anglicky Tisk
Skladem
9486 Kč
Označení normy:BS EN 60534-2-1:2011
Počet stran:60
Vydáno:2015-06-30
ISBN:978 0 580 90345 8
Status:Standard
Popis

BS EN 60534-2-1:2011


This standard BS EN 60534-2-1:2011 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC. Equipment for testing, measuring or monitoring of protective measures is classified in these ICS categories:
  • 23.060.40 Pressure regulators
  • 25.040.40 Industrial process measurement and control
  • 17.220.20 Measurement of electrical and magnetic quantities
  • 29.080.01 Electrical insulation in general
  • 29.240.01 Power transmission and distribution networks in general

This part of IEC 60534 includes equations for predicting the flow of compressible and incompressible fluids through control valves.

The equations for incompressible flow are based on standard hydrodynamic equations for Newtonian incompressible fluids. They are not intended for use when non-Newtonian fluids, fluid mixtures, slurries or liquid-solid conveyance systems are encountered. The equations for incompressible flow may be used with caution for non-vaporizing multi-component liquid mixtures. Refer to Clause 6 for additional information.

At very low ratios of pressure differential to absolute inlet pressure (∆ p/ p 1 ), compressible fluids behave similarly to incompressible fluids. Under such conditions, the sizing equations for compressible flow can be traced to the standard hydrodynamic equations for Newtonian incompressible fluids. However, increasing values of ∆ p/ p 1 result in compressibility effects which require that the basic equations be modified by appropriate correction factors. The equations for compressible fluids are for use with ideal gas or vapor and are not intended for use with multiphase streams such as gas-liquid, vapor-liquid or gas-solid mixtures. Reasonable accuracy can only be maintained when the specific heat ratio, γ, is restricted to the range 1,08 < γ < 1,65. Refer to Clause 7.2 for more information.

For compressible fluid applications, this standard is valid for valves with x T  ≤ 0,84 (see Table D.2). For valves with x T  > 0,84 (e.g. some multistage valves), greater inaccuracy of flow prediction can be expected.

Reasonable accuracy can only be maintained for control valves if:

[Formula removed.]

Note that while the equation structure utilized in this document departs radically from previous versions of the standard, the basic technology is relatively unchanged. The revised equation format was adopted to simplify presentation of the various equations and improve readability of the document.