Cena s DPH / bez DPH
Hlavní stránka>BS EN 60601-2-44:2009+A2:2016 Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography
Sponsored link
sklademVydáno: 2016-07-31
BS EN 60601-2-44:2009+A2:2016 Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography

BS EN 60601-2-44:2009+A2:2016

Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9280 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
928.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2784.00 Kč
Anglicky Tisk
Skladem
9280 Kč
Označení normy:BS EN 60601-2-44:2009+A2:2016
Počet stran:68
Vydáno:2016-07-31
ISBN:978 0 580 90493 6
Status:Standard
Popis

BS EN 60601-2-44:2009+A2:2016


This standard BS EN 60601-2-44:2009+A2:2016 Medical electrical equipment is classified in these ICS categories:
  • 11.040.50 Radiographic equipment

201.1.1 Scope

Replacement:

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of CT SCANNERS, hereafter also referred to as ME EQUIPMENT.

If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

NOTE 1 See also 4.2 of the general standard.

The scope of this document is limited to CT SCANNERS intended to be used for both head and body characterised by an ENCLOSURE of the X-ray source(s) and imaging detector(s) in a common protective cover in the shape of a toroid. It includes safety requirements for the X - RAY GENERATORS used in CT SCANNERS, including those where HIGH-VOLTAGE GENERATORS a reintegrated with an X-RAY TUBE ASSEMBLY.

NOTE 2 Requirements for X-RAY GENERATORS and for ASSOCIATED EQUIPMENT, which w ere previously specified in IEC 60601-2-7 and IEC 60601-2-32, have been included in either IEC 60601-1:2005 (Ed3) or this edition of IEC 60601-2-44. Therefore IEC 60601-2-7 and IEC 60601-2-32 are not part of the 3rd edition scheme for COMPUTED TOMOGRAPHY.

The scope of this International Standard excludes radiotherapy simulators and systems where the image is created by a source other than an X-ray tube.