Cena s DPH / bez DPH
Hlavní stránka>BS EN 60601-2-62:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment
Sponsored link
sklademVydáno: 2015-06-30
BS EN 60601-2-62:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment

BS EN 60601-2-62:2015

Medical electrical equipment Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9734 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
973.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2920.20 Kč
Anglicky Tisk
Skladem
9734 Kč
Označení normy:BS EN 60601-2-62:2015
Počet stran:72
Vydáno:2015-06-30
ISBN:978 0 580 65039 0
Status:Standard
Popis

BS EN 60601-2-62:2015


This standard BS EN 60601-2-62:2015 Medical electrical equipment is classified in these ICS categories:
  • 11.040.01 Medical equipment in general
  • 17.140.50 Electroacoustics
IEC 60601-2-62:2013 applies to the basic safety and essential performance of HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT. This International Standard adds or replaces clauses listed in the IEC 60601-1 that are specific for HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT. If a clause or subclause is specifically intended to be applicable to such equipment only, or to related systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to individual equipment and to systems, as relevant. Hazards inherent in the intended physiological function of the equipment or systems within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. This standard can also be applied to
- therapeutic equipment for thrombolysis through exposure to high-intensity therapeutic ultrasound;
- therapeutic equipment for the treatment of occluding feeding vessels through exposure to high-intensity focused ultrasound;
- and equipment intended to be used for relieving cancer pain due to bone metastases.
This particular standard does not apply to
- Ultrasound Equipment intended to be used for physiotherapy (use IEC 60601-2-5 and IEC 61689);
- Ultrasound Equipment intended to be used for lithotripsy (use IEC 60601-2-36);
- Ultrasound Equipment intended to be used for dedicated hyperthermia devices; and
- Ultrasound Equipment intended to be used for phacoemulsification.