Cena s DPH / bez DPH
Hlavní stránka>BS EN 61000-4-19:2014 Electromagnetic compatibility (EMC) Testing and measurement techniques. Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
Sponsored link
sklademVydáno: 2014-09-30
BS EN 61000-4-19:2014 Electromagnetic compatibility (EMC) Testing and measurement techniques. Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports

BS EN 61000-4-19:2014

Electromagnetic compatibility (EMC) Testing and measurement techniques. Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7564 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
756.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2269.20 Kč
Anglicky Tisk
Skladem
7564 Kč
Označení normy:BS EN 61000-4-19:2014
Počet stran:36
Vydáno:2014-09-30
ISBN:978 0 580 77968 8
Status:Standard
Popis

BS EN 61000-4-19:2014


This standard BS EN 61000-4-19:2014 Electromagnetic compatibility (EMC) is classified in these ICS categories:
  • 33.100.20 Immunity

This part of IEC 61000 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports.

The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of differential mode disturbances and signalling to a.c. power ports. This standard defines:

  • test waveforms;

  • range of test levels;

  • test equipment;

  • test setup;

  • test procedures;

  • verification procedures.

These tests are intended to demonstrate the immunity of electrical and electronic equipment operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential mode disturbances such as those originating from power electronics and power line communication systems (PLC).

NOTE

In some countries, the maximum voltage can be as much as 350 V from phase to neutral.

The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports up to 2 kHz in differential mode is covered by IEC 61000‑4‑13 .

Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and common mode components. This standard provides immunity tests only for differential mode disturbances and signalling. It is recommended to perform common mode tests as well, which are covered by IEC 61000‑4‑16 .