Hlavní stránka>BS EN 61000-4-6:2014 Electromagnetic compatibility (EMC) Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields
Sponsored link
sklademVydáno: 2014-02-28
BS EN 61000-4-6:2014 Electromagnetic compatibility (EMC) Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields

BS EN 61000-4-6:2014

Electromagnetic compatibility (EMC) Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
10230 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
1023.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
3069.00 Kč
Anglicky Tisk
Skladem
10230 Kč
Označení normy:BS EN 61000-4-6:2014
Počet stran:88
Vydáno:2014-02-28
ISBN:978 0 580 69973 3
Status:Standard
Popis

BS EN 61000-4-6:2014


This standard BS EN 61000-4-6:2014 Electromagnetic compatibility (EMC) is classified in these ICS categories:
  • 33.100.20 Immunity
IEC 61000-4-6:2013 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz. Equipment not having at least one conducting wire and/or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this publication. The object of this standard is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method documented in IEC 61000-4-6:2013 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This fourth edition cancels and replaces the third edition published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to the previous edition:
- use of the CDNs;
- calibration of the clamps;
- reorganization of Clause 7 on test setup and injection methods;
- Annex A which is now dedicated to EM and decoupling clamps;
- Annex G which now addresses the measurement uncertainty of the voltage test level;
- and informative Annexes H, I and J which are new. The contents of the corrigendum of June 2015 have been included in this copy.