Cena s DPH / bez DPH
Hlavní stránka>BS EN 61000-5-5:1996 Electromagnetic compatibility (EMC). Installation and mitigation guidelines Specification of protective devices for HEMP conducted disturbance. Basic EMC publication
sklademVydáno: 1996-12-15
BS EN 61000-5-5:1996 Electromagnetic compatibility (EMC). Installation and mitigation guidelines Specification of protective devices for HEMP conducted disturbance. Basic EMC publication

BS EN 61000-5-5:1996

Electromagnetic compatibility (EMC). Installation and mitigation guidelines Specification of protective devices for HEMP conducted disturbance. Basic EMC publication

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6240 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
624.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1872.00 Kč
Anglicky Tisk
Skladem
6240 Kč
Označení normy:BS EN 61000-5-5:1996
Počet stran:30
Vydáno:1996-12-15
ISBN:0 580 26381 9
Status:Standard
Popis

BS EN 61000-5-5:1996


This standard BS EN 61000-5-5:1996 Electromagnetic compatibility (EMC). Installation and mitigation guidelines is classified in these ICS categories:
  • 33.100.01 Electromagnetic compatibility in general

This part of IEC 1000-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. It is intended to be used for the harmonization of existing or future specifications issued by protective device manufacturers, electronic equipment manufacturers, administrations and other ultimate buyers. Performance requirements shall be given in future IEC documents.

This section covers protective devices currently being used for protection against induced HEMP transients on signal and low voltage power lines (nominal voltage up to 1 kV a.c.).

General information can be applied also to high voltage lines. However, in these cases, the additional requirements for the protection levels of existing lightning arresters (especially gapless MO-arresters) are under consideration.

In general, HEMP-relevant parameters, i.e. parameters related to very fast changes of electromagnetic field, voltage (u) and current (i) as a function of time, are of interest. For basic specifications, reference is made to other relevant standards (see annex E) dealing with phenomena other than HEMP. When such standards do not adequately consider the requirements of modern electronics, additional specifications, modifications or extensions based on non-HEMP-relevant standards are defined.


Defines how to specify devices for protection against conducted disturbance resulting from HEMP.