BS EN 61243-5:2001 Live working. Voltage detectors Voltage detecting systems (VDS)

BS EN 61243-5:2001

Live working. Voltage detectors Voltage detecting systems (VDS)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9486 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
948.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2845.80 Kč
Anglicky Tisk
Skladem
9486 Kč
Označení normy:BS EN 61243-5:2001
Počet stran:68
Vydáno:2001-08-15
ISBN:0 580 38089 0
Status:Standard
Popis

BS EN 61243-5:2001


This standard BS EN 61243-5:2001 Live working. Voltage detectors is classified in these ICS categories:
  • 13.260 Protection against electric shock. Live working

This part of IEC 61243 is applicable to voltage detecting systems that are single-pole and are capacitively-coupled to live parts. They are used to detect the presence or absence of operating voltage on a.c. electrical systems for voltages from 1 kV to 52 kV, and for frequencies from 162/3 Hz to 60 Hz.

This standard is also applicable to phase comparators designed for voltage detecting systems.

EMC tests are not included as, at the present time, not enough information about minimum requirements is available.

NOTES

  1. Except where specified otherwise, all the voltages defined in this standard refer to values of phase-to-phase voltages of three-phase systems. In other systems, the applicable phase-to-phase or phase-to-earth voltages are used to determine the operating voltage.

  2. Voltage detecting systems based on fundamentally different principles (for example optical systems, resistive coupling elements) are not covered in this standard but should meet the requirements of this standard where applicable.

  3. For frequencies differing from 50 Hz, the values Cs and Ut according to table 1 are valid. The threshold values for It have to be changed accordingly.

  4. If in an electrical installation it is verified that the installation is dead by other means than using a voltage detecting system, a different device which can be termed voltage indicating system may be used for service information about the voltage state with reduced requirements concerning tests for clear and reliable indication. If so, this should be clearly stated and made explicit by the manufacturer (see annex F for further details).