BS EN 61285:2015 Industrial-process control. Safety of analyzer houses

BS EN 61285:2015

Industrial-process control. Safety of analyzer houses

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6820 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
682.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2046.00 Kč
Anglicky Tisk
Skladem
6820 Kč
Označení normy:BS EN 61285:2015
Počet stran:30
Vydáno:2015-04-30
ISBN:978 0 580 80698 8
Status:Standard
Popis

BS EN 61285:2015


This standard BS EN 61285:2015 Industrial-process control. Safety of analyzer houses is classified in these ICS categories:
  • 13.110 Safety of machinery
  • 25.040.40 Industrial process measurement and control

This International Standard describes the physical requirements for the safe operation of the process analyser measuring system installed in an analyser house (AH) in order to ensure its protection against fire, explosion and health hazards. This standard applies for analyser houses with inner and/or external potential explosive atmospheres and it applies to hazards caused by toxic substances or asphyxiant gases. (Refer to national guidelines on toxic hazards.)

This standard does not address facilities where solids (dust, powder, fibres) are the hazard.

This standard does not seek to address all functional safety issues related to analyser houses.

Clause 4 addresses the location of the AH and connection within the process plant areas.

Clause 5 addresses the design, construction and layout of the AH. It does not address parts of the analyser measuring system installed in other locations such as sample conditioning rooms (SCR) or switchgear rooms.

Clause 6 addresses measures for reducing the danger of explosion for AHs while permitting maintenance of equipment with the power on and the case open.

For most fluids, the major constraint is that the concentration of vapours, which are toxic for personnel, is lower than the lower explosive (flammable) limit (LEL) (see Clause 7).

Using n-Pentane as an example, the LEL is 1,4 % or 14 000 × 10 –6, the level immediately dangerous to life or health (which is the maximum level from which a worker could escape within 30 min without any escape-impairing symptoms or any irreversible health effects) is only 0,5 % or 5 000 × 10 –6.

Clause 7 addresses those measures for protecting personnel from materials in the atmosphere of AHs that are hazardous to health.